IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

42

matching recommendations
Reset
NAICS 335 Electrical Equipment, Appliance, and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0749 # 02 Y:2015 02 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $24,207 $1,000 Implemented
MA0749 # 01 Y:2015 01 2015 REDUCE VENTILATION AIR $30,757 $20,400 Implemented
MA0749 # 12 Y:2015 12 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $1,079 $100 Implemented
MA0749 # 11 Y:2015 11 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $1,227 $1,013 Not Implemented
MA0749 # 10 Y:2015 10 2015 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,592 $500 Not Implemented
MA0749 # 09 Y:2015 09 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $3,372 $1,000 Implemented
MA0749 # 08 Y:2015 08 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,495 $500 Not Implemented
MA0749 # 07 Y:2015 07 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,067 $3,000 Implemented
MA0749 # 06 Y:2015 06 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,856 $24,500 Implemented
MA0749 # 05 Y:2015 05 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $8,523 $1,000 Not Implemented
MA0749 # 04 Y:2015 04 2015 OPTIMIZE PLANT POWER FACTOR $10,366 $25,300 Not Implemented
MA0749 # 03 Y:2015 03 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,980 $3,330 Implemented
MA0705 # 07 Y:2013 07 2013 PAY UTILITY BILLS ON TIME $1,191 $500 Implemented
MA0705 # 06 Y:2013 06 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,632 $4,231 Not Implemented
MA0705 # 05 Y:2013 05 2013 OPTIMIZE PLANT POWER FACTOR $3,939 $13,700 Implemented
MA0705 # 04 Y:2013 04 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,037 $8,350 Not Implemented
MA0705 # 03 Y:2013 03 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,053 $2,800 Implemented
MA0705 # 02 Y:2013 02 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,284 $19,400 Implemented
MA0705 # 01 Y:2013 01 2013 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $8,642 $200 Not Implemented
MA0705 # 08 Y:2013 08 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $244 $497 Not Implemented
MA0693 # 04 Y:2012 04 2012 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,573 $27,000 Not Implemented
MA0693 # 03 Y:2012 03 2012 REPAIR AND ELIMINATE STEAM LEAKS $9,000 $4,200 Implemented
MA0693 # 02 Y:2012 02 2012 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,776 $43,000 Not Implemented
MA0693 # 07 Y:2012 07 2012 INSULATE BARE EQUIPMENT $373 $600 Not Implemented
MA0693 # 05 Y:2012 05 2012 INSTALL OCCUPANCY SENSORS $1,572 $4,200 Implemented