Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
736
matching recommendationsNAICS | 3353 | Electrical Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0150 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,543 | $1,074 | Not Implemented |
MI0150 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,741 | $5,000 | Not Implemented |
MI0150 # 07 Y:2007 | 07 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,315 | $2,627 | Not Implemented |
MI0150 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,220 | $30 | Implemented |
MI0150 # 09 Y:2007 | 09 | 2007 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,658 | $300 | Implemented |
MI0150 # 10 Y:2007 | 10 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,203 | $240 | Not Implemented |
MI0150 # 11 Y:2007 | 11 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $651 | $3,010 | Not Implemented |
IC0119 # 01 Y:2006 | 01 | 2006 | RECOVER AND REUSE SPENT ACID BATHS | $32,160 | $82,800 | Not Implemented |
IC0119 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,829 | $600 | Implemented |
IC0119 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,559 | $114,725 | Implemented |
IC0119 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,402 | $61,775 | Implemented |
IC0119 # 05 Y:2006 | 05 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $33,836 | $144,000 | Not Implemented |
IC0119 # 06 Y:2006 | 06 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $130,000 | $0 | Not Implemented |
IC0119 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,048 | $38,744 | Implemented |
IC0119 # 08 Y:2006 | 08 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $30,353 | $312,000 | Not Implemented |
LE0232 # 01 Y:2006 | 01 | 2006 | MODIFY WORKLOAD | $35,100 | $3,200 | Not Implemented |
LE0232 # 02 Y:2006 | 02 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $33,102 | $38,465 | Not Implemented |
LE0232 # 03 Y:2006 | 03 | 2006 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $7,750 | $3,510 | Not Implemented |
LE0232 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,787 | $500 | Not Implemented |
LE0232 # 05 Y:2006 | 05 | 2006 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,612 | $620 | Not Implemented |
LE0232 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $809 | $60 | Not Implemented |
LE0232 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $363 | $500 | Not Implemented |
LE0232 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $7,549 | $2,440 | Not Implemented |
LE0232 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,445 | $51,983 | Not Implemented |
CO0574 # 01 Y:2005 | 01 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $37,120 | $6,000 | Not Implemented |