Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,027
matching recommendationsNAICS | 3359 | Other Electrical Equipment and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0003 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $348 | $1,250 | Not Implemented |
NL0003 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $200 | $250 | Not Implemented |
WV0544 # 01 Y:2017 | 01 | 2017 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $455,414 | $1,455,300 | Not Implemented |
WV0544 # 02 Y:2017 | 02 | 2017 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $113,487 | $482,000 | Not Implemented |
WV0544 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $65,441 | $142,350 | Not Implemented |
WV0544 # 04 Y:2017 | 04 | 2017 | RECYCLE WHITE WATER | $61,512 | $25,000 | Implemented |
WV0544 # 05 Y:2017 | 05 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $50,032 | $125,526 | Not Implemented |
WV0544 # 06 Y:2017 | 06 | 2017 | INCREASE AMOUNT OF CONDENSATE RETURNED | $26,543 | $125,000 | Not Implemented |
WV0544 # 07 Y:2017 | 07 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,362 | $0 | Implemented |
WV0544 # 08 Y:2017 | 08 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $10,299 | $1,000 | Implemented |
WV0544 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,346 | $25,467 | Not Implemented |
WV0544 # 10 Y:2017 | 10 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $4,065 | $1,108 | Implemented |
WV0544 # 11 Y:2017 | 11 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $3,967 | $15,395 | Not Implemented |
WV0544 # 12 Y:2017 | 12 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,588 | $2,000 | Implemented |
WV0544 # 13 Y:2017 | 13 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,526 | $732 | Implemented |
WV0544 # 14 Y:2017 | 14 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,358 | $3,438 | Not Implemented |
WV0544 # 15 Y:2017 | 15 | 2017 | INSULATE BARE EQUIPMENT | $268 | $876 | Not Implemented |
NC0575 # 01 Y:2016 | 01 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,250 | $500 | Implemented |
NC0575 # 02 Y:2016 | 02 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,087 | $100 | Implemented |
NC0575 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,862 | $21,540 | Not Implemented |
NC0575 # 04 Y:2016 | 04 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $750 | $475 | Implemented |
NC0575 # 05 Y:2016 | 05 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $338 | $100 | Not Implemented |
NC0575 # 06 Y:2016 | 06 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $158 | $300 | Not Implemented |
NC0571 # 01 Y:2016 | 01 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $59,225 | $500 | Not Implemented |
NC0571 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $57,529 | $69,600 | Not Implemented |