Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
301
matching recommendationsNAICS | 33593 | Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0352 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,302 | $1,278 | Not Implemented |
UF0352 # 10 Y:2004 | 10 | 2004 | IMPROVE SPACE COMFORT CONDITIONING | $40,000 | $5,000 | Not Implemented |
UF0352 # 11 Y:2004 | 11 | 2004 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $21,450 | $0 | Not Implemented |
UF0352 # 12 Y:2004 | 12 | 2004 | RECYCLE FLUORESCENT LAMPS | $1,214 | $3,496 | Not Implemented |
WV0289 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $46,305 | $117,949 | Not Implemented |
WV0289 # 02 Y:2004 | 02 | 2004 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $16,901 | $11,831 | Not Implemented |
WV0289 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,600 | $4,857 | Implemented |
WV0289 # 04 Y:2004 | 04 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $9,956 | $2,109 | Implemented |
WV0289 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,230 | $1,687 | Implemented |
WV0289 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,338 | $19,000 | Not Implemented |
WV0289 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,340 | $127 | Implemented |
WV0289 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $3,010 | $5,938 | Not Implemented |
WV0289 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,993 | $250 | Implemented |
WV0289 # 10 Y:2004 | 10 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,879 | $511 | Not Implemented |
WV0289 # 11 Y:2004 | 11 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,432 | $3,500 | Not Implemented |
WV0289 # 12 Y:2004 | 12 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,170 | $103 | Implemented |
WV0289 # 13 Y:2004 | 13 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,628 | $1,119 | Not Implemented |
WV0289 # 14 Y:2004 | 14 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,227 | $1,631 | Implemented |
WV0289 # 15 Y:2004 | 15 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,365 | $0 | Implemented |
MI0075 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,278 | $600 | Not Implemented |
MI0075 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,540 | $1,300 | Implemented |
MI0075 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,940 | $0 | Implemented |
MI0075 # 04 Y:2004 | 04 | 2004 | CLEAR AND RENT EXISTING SPACE | $124,576 | $9,800 | Implemented |
MI0075 # 05 Y:2004 | 05 | 2004 | CLEAR AND RENT EXISTING SPACE | $42,330 | $1,600 | Implemented |
MI0075 # 06 Y:2004 | 06 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,088 | $60 | Not Implemented |