Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsNAICS | 33593 | Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0058 # 05 Y:2003 | 05 | 2003 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $20,000 | $19,260 | n/a |
LM0058 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $6,265 | $2,028 | Implemented |
LM0058 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,012 | $18,500 | Not Implemented |
LM0058 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,174 | $250 | Implemented |
LM0058 # 01 Y:2003 | 01 | 2003 | ADD AREA LIGHTING SWITCHES | $6,786 | $7,274 | Implemented |
LM0055 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,231 | $1,300 | Implemented |
LM0055 # 08 Y:2003 | 08 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $277,680 | $6,344 | Not Implemented |
LM0055 # 07 Y:2003 | 07 | 2003 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $215,000 | $20,000 | Implemented |
LM0055 # 06 Y:2003 | 06 | 2003 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,900 | $2,572 | Not Implemented |
LM0055 # 05 Y:2003 | 05 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,902 | $5,187 | Not Implemented |
LM0055 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $40,209 | $27,572 | Implemented |
LM0055 # 02 Y:2003 | 02 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $26,748 | $10,240 | Not Implemented |
LM0055 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,172 | $120 | Implemented |
AS0348 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $164 | $101 | Implemented |
AS0348 # 06 Y:2003 | 06 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $93,399 | $45,312 | Not Implemented |
AS0348 # 05 Y:2003 | 05 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $413 | $2,000 | Implemented |
AS0348 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,021 | $450 | Implemented |
AS0348 # 03 Y:2003 | 03 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,000 | $15,500 | Not Implemented |
AS0348 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,361 | $16,680 | Implemented |