Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
105
matching recommendationsNAICS | 335931 | Current-Carrying Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0474 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $357 | $650 | Implemented |
SU0474 # 05 Y:2019 | 05 | 2019 | OPTIMIZE PLANT POWER FACTOR | $8,523 | $18,735 | Implemented |
MI0320 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $53,871 | $1,660 | Implemented |
MI0320 # 04 Y:2017 | 04 | 2017 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $40,560 | $27,600 | Implemented |
MI0320 # 02 Y:2017 | 02 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $58,406 | $120 | Implemented |
MI0320 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $18,035 | $23,565 | Implemented |
MI0320 # 05 Y:2017 | 05 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $23,860 | $3,600 | Implemented |
MZ0203 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,707 | $11,425 | Implemented |
MZ0203 # 03 Y:2016 | 03 | 2016 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $324 | $1,975 | Implemented |
MZ0203 # 01 Y:2016 | 01 | 2016 | INSTALL OCCUPANCY SENSORS | $3,747 | $680 | Implemented |
SU0375 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $221 | $539 | Implemented |
SU0375 # 07 Y:2014 | 07 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $496 | $2,007 | Implemented |
SU0375 # 02 Y:2014 | 02 | 2014 | PAY BILLS ON TIME TO AVOID LATE FEES | $291 | $0 | Implemented |
SU0375 # 03 Y:2014 | 03 | 2014 | DISCONNECT BALLASTS | $148 | $0 | Implemented |
SU0375 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $765 | Implemented |
MA0694 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $2,300 | $16,608 | Implemented |
MA0694 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $503 | $900 | Implemented |
MA0694 # 03 Y:2012 | 03 | 2012 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $5,619 | $0 | Implemented |
MA0694 # 01 Y:2012 | 01 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,023 | $500 | Implemented |
MI0215 # 05 Y:2012 | 05 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,815 | $1,300 | Implemented |
MI0215 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,517 | $8,000 | Implemented |
NC0435 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $44,479 | $72,211 | Implemented |
NC0435 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $661 | $1,911 | Implemented |
NC0435 # 03 Y:2011 | 03 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,887 | $7,760 | Implemented |
NC0435 # 06 Y:2011 | 06 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $295 | $1,500 | Implemented |