Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
226
matching recommendationsNAICS | 335931 | Current-Carrying Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0320 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $18,035 | $23,565 | Implemented |
MI0320 # 08 Y:2017 | 08 | 2017 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,716 | $6,530 | Not Implemented |
MI0320 # 07 Y:2017 | 07 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,588 | $2,300 | Not Implemented |
MZ0203 # 01 Y:2016 | 01 | 2016 | INSTALL OCCUPANCY SENSORS | $3,747 | $680 | Implemented |
MZ0203 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,707 | $11,425 | Implemented |
MZ0203 # 03 Y:2016 | 03 | 2016 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $324 | $1,975 | Implemented |
MZ0203 # 04 Y:2016 | 04 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,109 | $37,500 | Not Implemented |
SU0375 # 08 Y:2014 | 08 | 2014 | ELIMINATE/REDUCE AN OPERATION | $388 | $1,660 | Not Implemented |
SU0375 # 07 Y:2014 | 07 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $496 | $2,007 | Implemented |
SU0375 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $221 | $539 | Implemented |
SU0375 # 05 Y:2014 | 05 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $580 | $1,126 | Not Implemented |
SU0375 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $765 | Implemented |
SU0375 # 03 Y:2014 | 03 | 2014 | DISCONNECT BALLASTS | $148 | $0 | Implemented |
SU0375 # 02 Y:2014 | 02 | 2014 | PAY BILLS ON TIME TO AVOID LATE FEES | $291 | $0 | Implemented |
SU0375 # 01 Y:2014 | 01 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,635 | $0 | Not Implemented |
MA0694 # 01 Y:2012 | 01 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,023 | $500 | Implemented |
MA0694 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $7,473 | $0 | Not Implemented |
MA0694 # 03 Y:2012 | 03 | 2012 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $5,619 | $0 | Implemented |
MA0694 # 04 Y:2012 | 04 | 2012 | INSULATE BARE EQUIPMENT | $3,042 | $665 | Not Implemented |
MA0694 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $2,300 | $16,608 | Implemented |
MA0694 # 06 Y:2012 | 06 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,515 | $3,410 | Not Implemented |
MA0694 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $503 | $900 | Implemented |
MA0694 # 08 Y:2012 | 08 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $253 | $900 | Not Implemented |
MI0215 # 07 Y:2012 | 07 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $625 | $4,571 | Not Implemented |
MI0215 # 05 Y:2012 | 05 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,815 | $1,300 | Implemented |