Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

324

matching recommendations
Reset
NAICS 33599 All Other Electrical Equipment and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0604 # 02 Y:2013 02 2013 IMPROVE COMBUSTION CONTROL CAPABILITY $144,955 $110,000 Not Implemented
OR0604 # 03 Y:2013 03 2013 RECOVER WASTE HEAT FROM EQUIPMENT $53,512 $43,218 Not Implemented
OR0604 # 04 Y:2013 04 2013 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $13,502 $5,712 Not Implemented
OR0604 # 05 Y:2013 05 2013 UPGRADE CONTROLS ON COMPRESSORS $11,228 $11,850 Implemented
SF0426 # 01 Y:2013 01 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,719 $0 Not Implemented
SF0426 # 02 Y:2013 02 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $1,686 $0 Not Implemented
SF0426 # 03 Y:2013 03 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $8,403 $649 Not Implemented
SF0426 # 04 Y:2013 04 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,301 $7,526 Not Implemented
SF0426 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $373 $1,619 Not Implemented
SF0426 # 06 Y:2013 06 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,979 $17,191 Implemented
UA3025 # 01 Y:2013 01 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $38,774 $8,081 Implemented
UA3025 # 02 Y:2013 02 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $26,515 $2,400 Not Implemented
UA3025 # 03 Y:2013 03 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $24,911 $4,000 Not Implemented
UA3025 # 04 Y:2013 04 2013 UPGRADE CONTROLS ON COMPRESSORS $18,334 $2,000 Not Implemented
UA3025 # 05 Y:2013 05 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $18,298 $18,000 Not Implemented
MZ0091 # 01 Y:2012 01 2012 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $190,000 $5,000 Implemented
MZ0091 # 02 Y:2012 02 2012 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $18,699 $0 Implemented
MZ0091 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $30,809 $27,800 Implemented
MZ0091 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,504 $0 Implemented
MZ0091 # 05 Y:2012 05 2012 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $3,133 $0 Implemented
MZ0091 # 06 Y:2012 06 2012 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $24,311 $9,516 Implemented
MA0693 # 01 Y:2012 01 2012 PAY UTILITY BILLS ON TIME $25,247 $500 Implemented
MA0693 # 02 Y:2012 02 2012 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,776 $43,000 Not Implemented
MA0693 # 03 Y:2012 03 2012 REPAIR AND ELIMINATE STEAM LEAKS $9,000 $4,200 Implemented
MA0693 # 04 Y:2012 04 2012 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,573 $27,000 Not Implemented