Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
324
matching recommendationsNAICS | 33599 | All Other Electrical Equipment and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0604 # 02 Y:2013 | 02 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $144,955 | $110,000 | Not Implemented |
OR0604 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $53,512 | $43,218 | Not Implemented |
OR0604 # 04 Y:2013 | 04 | 2013 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $13,502 | $5,712 | Not Implemented |
OR0604 # 05 Y:2013 | 05 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $11,228 | $11,850 | Implemented |
SF0426 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,719 | $0 | Not Implemented |
SF0426 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,686 | $0 | Not Implemented |
SF0426 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,403 | $649 | Not Implemented |
SF0426 # 04 Y:2013 | 04 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,301 | $7,526 | Not Implemented |
SF0426 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $373 | $1,619 | Not Implemented |
SF0426 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,979 | $17,191 | Implemented |
UA3025 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $38,774 | $8,081 | Implemented |
UA3025 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $26,515 | $2,400 | Not Implemented |
UA3025 # 03 Y:2013 | 03 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $24,911 | $4,000 | Not Implemented |
UA3025 # 04 Y:2013 | 04 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $18,334 | $2,000 | Not Implemented |
UA3025 # 05 Y:2013 | 05 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $18,298 | $18,000 | Not Implemented |
MZ0091 # 01 Y:2012 | 01 | 2012 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $190,000 | $5,000 | Implemented |
MZ0091 # 02 Y:2012 | 02 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,699 | $0 | Implemented |
MZ0091 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,809 | $27,800 | Implemented |
MZ0091 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,504 | $0 | Implemented |
MZ0091 # 05 Y:2012 | 05 | 2012 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,133 | $0 | Implemented |
MZ0091 # 06 Y:2012 | 06 | 2012 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $24,311 | $9,516 | Implemented |
MA0693 # 01 Y:2012 | 01 | 2012 | PAY UTILITY BILLS ON TIME | $25,247 | $500 | Implemented |
MA0693 # 02 Y:2012 | 02 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,776 | $43,000 | Not Implemented |
MA0693 # 03 Y:2012 | 03 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $9,000 | $4,200 | Implemented |
MA0693 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,573 | $27,000 | Not Implemented |