Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsNAICS | 33599 | All Other Electrical Equipment and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0125 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,851 | $18,588 | Implemented |
UU0125 # 03 Y:2017 | 03 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,110 | $20 | Not Implemented |
UU0125 # 04 Y:2017 | 04 | 2017 | RECOVER AND REUSE WASTE MATERIAL | $6,187 | $3,150 | Implemented |
UU0125 # 05 Y:2017 | 05 | 2017 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $5,417 | $39,198 | Not Implemented |
UU0125 # 06 Y:2017 | 06 | 2017 | INSTALL OCCUPANCY SENSORS | $4,418 | $7,220 | Implemented |
UU0125 # 07 Y:2017 | 07 | 2017 | MINIMIZE WATER USAGE | $3,700 | $200 | Implemented |
UU0125 # 08 Y:2017 | 08 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,690 | $0 | Not Implemented |
UU0125 # 01 Y:2017 | 01 | 2017 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $32,802 | $0 | Not Implemented |
NL0003 # 03 Y:2017 | 03 | 2017 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $1,586 | $4,300 | Not Implemented |
NL0003 # 02 Y:2017 | 02 | 2017 | ISOLATE HOT OR COLD EQUIPMENT | $1,797 | $14,000 | Implemented |
NL0003 # 01 Y:2017 | 01 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,412 | $15,000 | Not Implemented |
NL0003 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $348 | $1,250 | Not Implemented |
NL0003 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $200 | $250 | Not Implemented |
WV0544 # 06 Y:2017 | 06 | 2017 | INCREASE AMOUNT OF CONDENSATE RETURNED | $26,543 | $125,000 | Not Implemented |
WV0544 # 07 Y:2017 | 07 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,362 | $0 | Implemented |
WV0544 # 08 Y:2017 | 08 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $10,299 | $1,000 | Implemented |
WV0544 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,346 | $25,467 | Not Implemented |
WV0544 # 10 Y:2017 | 10 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $4,065 | $1,108 | Implemented |
WV0544 # 11 Y:2017 | 11 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $3,967 | $15,395 | Not Implemented |
WV0544 # 12 Y:2017 | 12 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,588 | $2,000 | Implemented |
WV0544 # 13 Y:2017 | 13 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,526 | $732 | Implemented |
WV0544 # 05 Y:2017 | 05 | 2017 | IMPROVE COMBUSTION CONTROL CAPABILITY | $50,032 | $125,526 | Not Implemented |
WV0544 # 04 Y:2017 | 04 | 2017 | RECYCLE WHITE WATER | $61,512 | $25,000 | Implemented |
WV0544 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $65,441 | $142,350 | Not Implemented |
WV0544 # 02 Y:2017 | 02 | 2017 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $113,487 | $482,000 | Not Implemented |