Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,763

matching recommendations
Reset
NAICS 336 Transportation Equipment Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1612 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,934 $3,000 Not Implemented
UK1612 # 04 Y:2017 04 2017 INSTALL SKYLIGHTS $9,639 $11,580 Not Implemented
UK1612 # 05 Y:2017 05 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,475 $3,350 Not Implemented
UK1612 # 06 Y:2017 06 2017 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $841 $72 Not Implemented
UK1612 # 07 Y:2017 07 2017 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,376 $3,000 Not Implemented
UK1612 # 08 Y:2017 08 2017 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,221 $7,597 Not Implemented
UK1612 # 09 Y:2017 09 2017 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,810 $3,352 Not Implemented
UK1612 # 10 Y:2017 10 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $835 $0 Not Implemented
UK1612 # 11 Y:2017 11 2017 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,333 $0 Not Implemented
UK1612 # 12 Y:2017 12 2017 INSULATE BARE EQUIPMENT $1,083 $1,584 Not Implemented
UK1612 # 13 Y:2017 13 2017 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,400 $422 Not Implemented
OK0962 # 01 Y:2017 01 2017 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,242 $3,615 Implemented
OK0962 # 02 Y:2017 02 2017 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $1,799 $6,750 Not Implemented
OK0962 # 03 Y:2017 03 2017 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $600 $160 Implemented
OK0962 # 04 Y:2017 04 2017 INSTALL SET-BACK TIMERS $378 $599 Implemented
OK0962 # 05 Y:2017 05 2017 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $311 $480 Implemented
OK0962 # 06 Y:2017 06 2017 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $304 $90 Not Implemented
OK0962 # 07 Y:2017 07 2017 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,765 $1,260 Not Implemented
OK0962 # 08 Y:2017 08 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,622 $680 Not Implemented
OK0962 # 09 Y:2017 09 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $712 $2,381 Implemented
OK0962 # 10 Y:2017 10 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $487 $1,180 Implemented
OK0962 # 11 Y:2017 11 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,547 $7,040 Not Implemented
OK0962 # 12 Y:2017 12 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $264 $1,120 Not Implemented
OK0962 # 13 Y:2017 13 2017 PAY UTILITY BILLS ON TIME $554 $0 Implemented
UA0173 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $62,936 $136,836 Not Implemented