Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
180
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0457 # 03 Y:2018 | 03 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $90 | $0 | Not Implemented |
SU0457 # 04 Y:2018 | 04 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $560 | $200 | Implemented |
SU0457 # 05 Y:2018 | 05 | 2018 | ELIMINATE/REDUCE AN OPERATION | $10,228 | $2,970 | Not Implemented |
SU0457 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,474 | $1,455 | Not Implemented |
SU0457 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $335 | $430 | Implemented |
SU0457 # 08 Y:2018 | 08 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,156 | $19,261 | Implemented |
SU0457 # 09 Y:2018 | 09 | 2018 | REDUCE VENTILATION AIR | $1,478 | $2,495 | Not Implemented |
SU0457 # 10 Y:2018 | 10 | 2018 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $288 | $1,051 | Implemented |
SU0387 # 01 Y:2015 | 01 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,803 | $0 | Not Implemented |
SU0387 # 02 Y:2015 | 02 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,211 | $0 | Not Implemented |
SU0387 # 03 Y:2015 | 03 | 2015 | INSULATE BARE EQUIPMENT | $988 | $858 | Not Implemented |
SU0387 # 04 Y:2015 | 04 | 2015 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $15,923 | $25,000 | Not Implemented |
SU0387 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $776 | $1,546 | Not Implemented |
SU0387 # 06 Y:2015 | 06 | 2015 | MAKE A NEW BY-PRODUCT | $20,522 | $100,000 | Not Implemented |
SU0359 # 01 Y:2014 | 01 | 2014 | INSULATE FEEDWATER TANK | $1,037 | $137 | Implemented |
SU0359 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,651 | $1,900 | Implemented |
SU0359 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $1,346 | $470 | Implemented |
SU0359 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $931 | $855 | Implemented |
SU0359 # 05 Y:2014 | 05 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $78,976 | $119,000 | Not Implemented |
SU0359 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,476 | $4,124 | Implemented |
SU0339 # 01 Y:2013 | 01 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,610 | $0 | Implemented |
SU0339 # 02 Y:2013 | 02 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $10,664 | $994 | Not Implemented |
SU0339 # 03 Y:2013 | 03 | 2013 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,064 | $125 | Implemented |
SU0339 # 04 Y:2013 | 04 | 2013 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $18,079 | $3,600 | Implemented |
SU0339 # 05 Y:2013 | 05 | 2013 | ADD AREA LIGHTING SWITCHES | $429 | $152 | Implemented |