IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

520

matching recommendations
Reset
NAICS 336 Transportation Equipment Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0410 # 01 Y:2012 01 2012 OPTIMIZE PLANT POWER FACTOR $7,109 $20,000 Not Implemented
UM0410 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,453 $11,580 Not Implemented
UM0410 # 03 Y:2012 03 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,779 $100 Implemented
UM0410 # 04 Y:2012 04 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,438 $2,000 Not Implemented
UM0410 # 05 Y:2012 05 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $682 $10 Not Implemented
UM0408 # 01 Y:2012 01 2012 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $13,566 $16,700 Not Implemented
UM0408 # 02 Y:2012 02 2012 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $10,324 $2,000 Implemented
UM0408 # 03 Y:2012 03 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,021 $1,500 Implemented
UM0408 # 04 Y:2012 04 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,447 $200 Not Implemented
UM0408 # 05 Y:2012 05 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $595 $100 Implemented
UM0408 # 06 Y:2012 06 2012 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $1,364 $0 Implemented
UM0408 # 07 Y:2012 07 2012 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,129 $1,000 Implemented
UM0407 # 01 Y:2012 01 2012 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $7,773 $15,000 Not Implemented
UM0407 # 02 Y:2012 02 2012 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $6,427 $2,000 Implemented
UM0407 # 03 Y:2012 03 2012 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $6,006 $8,000 Implemented
UM0407 # 04 Y:2012 04 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,966 $200 Not Implemented
UM0407 # 05 Y:2012 05 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,660 $1,500 Implemented
UM0407 # 06 Y:2012 06 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $480 $100 Implemented
UM0407 # 07 Y:2012 07 2012 INSTALL OCCUPANCY SENSORS $44 $20 Not Implemented
UM0407 # 08 Y:2012 08 2012 REVISE SMOKE CLEANUP FROM OPERATIONS $29,650 $25,800 Not Implemented
UM0407 # 09 Y:2012 09 2012 RECOVER WASTE HEAT FROM EQUIPMENT $6,121 $1,000 Implemented
UM0406 # 01 Y:2012 01 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $48,738 $10,000 Not Implemented
UM0406 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,375 $7,720 Implemented
UM0406 # 03 Y:2012 03 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $12,063 $3,600 Implemented
UM0406 # 04 Y:2012 04 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $37,146 $1,000 Not Implemented