Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
260
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0091 # 04 Y:2012 | 04 | 2012 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,203 | $0 | Implemented |
TT0079 # 01 Y:2011 | 01 | 2011 | DISCONNECT BALLASTS | $508 | $0 | Implemented |
TT0079 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $336 | $0 | Implemented |
TT0079 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $205 | $0 | Implemented |
TT0079 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $1,618 | $0 | Not Implemented |
TT0079 # 05 Y:2011 | 05 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $631 | $0 | Not Implemented |
TT0079 # 06 Y:2011 | 06 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,937 | $0 | Implemented |
TT0079 # 07 Y:2011 | 07 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,691 | $0 | Not Implemented |
TT0079 # 08 Y:2011 | 08 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,584 | $0 | Not Implemented |
TT0060 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,900 | $23,000 | Not Implemented |
TT0060 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,000 | $39,900 | Not Implemented |
TT0060 # 03 Y:2011 | 03 | 2011 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $51,500 | $98,000 | Not Implemented |
TT0060 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,700 | $4,900 | Not Implemented |
TT0060 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,200 | $4,700 | Not Implemented |
TT0060 # 06 Y:2011 | 06 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,700 | $8,000 | Not Implemented |
TT0060 # 07 Y:2011 | 07 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $28,000 | $53,000 | Not Implemented |
TT0060 # 08 Y:2011 | 08 | 2011 | REVISE SMOKE CLEANUP FROM OPERATIONS | $22,900 | $20,000 | Not Implemented |
TT0060 # 09 Y:2011 | 09 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $9,800 | $200 | Not Implemented |
TT0060 # 10 Y:2011 | 10 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $3,700 | $1,600 | Not Implemented |
TT0060 # 11 Y:2011 | 11 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $600 | Not Implemented |
TT0060 # 12 Y:2011 | 12 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,280 | $0 | Not Implemented |
TT0048 # 01 Y:2010 | 01 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $56,000 | $1,000 | Implemented |
TT0048 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $97,000 | $421,000 | Not Implemented |
TT0048 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,900 | $91,150 | Not Implemented |
TT0048 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,500 | $4,500 | Not Implemented |