Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsNAICS | 33611 | Automobile and Light Duty Motor Vehicle Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0320 # 03 Y:2012 | 03 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $18,749 | $42,038 | Not Implemented |
SU0320 # 04 Y:2012 | 04 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $391 | $1,332 | Not Implemented |
SU0320 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,671 | $37,046 | Not Implemented |
SU0320 # 06 Y:2012 | 06 | 2012 | MAKE A NEW BY-PRODUCT | $21,685 | $100,000 | Not Implemented |
SU0320 # 07 Y:2012 | 07 | 2012 | ELIMINATE/REDUCE AN OPERATION | $2,644 | $15,840 | Not Implemented |
UMS002 # 01 Y:2012 | 01 | 2012 | INSULATE BARE EQUIPMENT | $1,300 | $1,000 | Not Implemented |
UMS002 # 02 Y:2012 | 02 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $67,000 | $50,000 | Not Implemented |
DL0073 # 01 Y:2011 | 01 | 2011 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $904,000 | $2,850,000 | Not Implemented |
DL0073 # 02 Y:2011 | 02 | 2011 | REPLACE BOILER | $420,000 | $408,000 | Not Implemented |
DL0073 # 03 Y:2011 | 03 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $19,700 | $6,400 | Not Implemented |
UA0061 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $223,288 | $22,500 | Implemented |
UA0061 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $224,396 | $387,720 | Not Implemented |
UA0061 # 03 Y:2011 | 03 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $27,256 | $85,000 | Not Implemented |
UA0061 # 04 Y:2011 | 04 | 2011 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $98,700 | $112,800 | Not Implemented |
UA0061 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $164,422 | $19,809 | Not Implemented |
UA0061 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $411,224 | $71,550 | Not Implemented |
DL0068 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,500 | $200 | Implemented |
DL0068 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,200 | $3,200 | Implemented |
DL0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,300 | $12,000 | Implemented |
DL0068 # 04 Y:2011 | 04 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $182,000 | $17,000 | Not Implemented |
DL0068 # 05 Y:2011 | 05 | 2011 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $21,659 | $4,300 | Implemented |
DL0068 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $51,400 | $10,000 | Implemented |
DL0068 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,315 | $15,000 | Not Implemented |
DL0068 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $183,000 | $600,000 | Not Implemented |
DL0068 # 09 Y:2011 | 09 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $32,300 | $200 | Implemented |