Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

23

matching recommendations
Reset
NAICS 336213 Motor Home Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0490 # 10 Y:2014 10 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $381 $51 Not Implemented
WV0490 # 09 Y:2014 09 2014 RECOVER WASTE HEAT FROM EQUIPMENT $701 $1,075 Not Implemented
WV0490 # 08 Y:2014 08 2014 REPLACE BOILER $1,367 $5,170 Implemented
WV0490 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,569 $3,905 Implemented
WV0490 # 06 Y:2014 06 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,812 $500 Implemented
WV0490 # 05 Y:2014 05 2014 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $2,052 $10,000 Implemented
WV0490 # 04 Y:2014 04 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,449 $364 Implemented
WV0490 # 03 Y:2014 03 2014 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $3,124 $1,000 Not Implemented
WV0490 # 02 Y:2014 02 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,883 $16,722 Implemented
WV0490 # 01 Y:2014 01 2014 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $10,882 $5,000 Implemented
WV0388 # 12 Y:2009 12 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $282 $590 Not Implemented
WV0388 # 13 Y:2009 13 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $246 $400 Not Implemented
WV0388 # 01 Y:2009 01 2009 USE RADIANT HEATER FOR SPOT HEATING $48,632 $54,244 Not Implemented
WV0388 # 11 Y:2009 11 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $321 $0 Not Implemented
WV0388 # 10 Y:2009 10 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $749 $572 Not Implemented
WV0388 # 09 Y:2009 09 2009 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,757 $4,680 Not Implemented
WV0388 # 08 Y:2009 08 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,801 $34 Implemented
WV0388 # 07 Y:2009 07 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,366 $3,122 Implemented
WV0388 # 06 Y:2009 06 2009 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,424 $6,259 Implemented
WV0388 # 05 Y:2009 05 2009 DEVELOP A REPAIR/REPLACE POLICY $2,746 $560 Implemented
WV0388 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,130 $1,763 Implemented
WV0388 # 03 Y:2009 03 2009 INSTALL OCCUPANCY SENSORS $3,159 $1,876 Implemented
WV0388 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,117 $51,755 Implemented