IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

192

matching recommendations
Reset
NAICS 3363 Motor Vehicle Parts Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0771 # 02 Y:2003 02 2003 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $17,568 $23,870 Implemented
GT0771 # 03 Y:2003 03 2003 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $882 $650 Implemented
GT0771 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,260 $1,050 Implemented
GT0771 # 05 Y:2003 05 2003 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $28,826 $1,248 Not Implemented
GT0771 # 06 Y:2003 06 2003 COVER OPEN TANKS $3,255 $3,703 Not Implemented
GT0771 # 07 Y:2003 07 2003 COVER OPEN TANKS $2,447 $3,500 Not Implemented
GT0771 # 08 Y:2003 08 2003 COVER OPEN TANKS $23,765 $700 Not Implemented
GT0771 # 09 Y:2003 09 2003 INSULATE BARE EQUIPMENT $29,561 $12,093 Not Implemented
GT0771 # 10 Y:2003 10 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,823 $0 Not Implemented
GT0771 # 01 Y:2003 01 2003 COMBINE UTILITY METERS $3,600 $0 Implemented
MI0069 # 03 Y:2003 03 2003 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $7,200 $3,222 Not Implemented
MI0069 # 01 Y:2003 01 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $46,943 $600 Not Implemented
MI0069 # 02 Y:2003 02 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $37,385 $2,100 Implemented
MI0069 # 06 Y:2003 06 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $147 $1,608 Not Implemented
MI0069 # 07 Y:2003 07 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $68,389 $68,389 Not Implemented
MI0069 # 05 Y:2003 05 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $11,691 $0 Implemented
MI0069 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,203 $3,536 Implemented
UD0682 # 07 Y:2003 07 2003 IMPROVE COMBUSTION CONTROL CAPABILITY $4,800 $2,000 Implemented
UD0682 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,062 $5,376 Not Implemented
UD0682 # 11 Y:2003 11 2003 INSTALL OCCUPANCY SENSORS $366 $428 Not Implemented
UD0682 # 04 Y:2003 04 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,809 $47,488 Not Implemented
UD0682 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,790 $3,000 Implemented
UD0682 # 09 Y:2003 09 2003 $2,596 $0 Implemented
UD0682 # 10 Y:2003 10 2003 DISCONNECT BALLASTS $1,534 $116 Not Implemented
UD0682 # 01 Y:2003 01 2003 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $27,674 $15,870 Not Implemented