Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
241
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1602 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,131 | $80,175 | Not Implemented |
UK1602 # 09 Y:2016 | 09 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,902 | $805 | Not Implemented |
UK1602 # 10 Y:2016 | 10 | 2016 | CHANGE PRODUCT SPECS | $3,827 | $675 | Not Implemented |
UK1602 # 11 Y:2016 | 11 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $815 | $0 | Not Implemented |
UK1602 # 12 Y:2016 | 12 | 2016 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $23,450 | $112,000 | Not Implemented |
UK1602 # 13 Y:2016 | 13 | 2016 | OPTIMIZE PLANT POWER FACTOR | $20,455 | $26,250 | Not Implemented |
UK1514 # 01 Y:2015 | 01 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,570 | $8,081 | Implemented |
UK1514 # 02 Y:2015 | 02 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $11,572 | $0 | Not Implemented |
UK1514 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,483 | $2,000 | Implemented |
UK1514 # 04 Y:2015 | 04 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,710 | $424 | Not Implemented |
UK1514 # 05 Y:2015 | 05 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21,417 | $0 | Implemented |
UK1514 # 06 Y:2015 | 06 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,377 | $0 | Not Implemented |
UK1514 # 07 Y:2015 | 07 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $925 | $343 | Implemented |
UK1514 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,674 | $5,574 | Not Implemented |
UK1514 # 09 Y:2015 | 09 | 2015 | INSTALL OCCUPANCY SENSORS | $1,704 | $2,189 | Implemented |
UK1514 # 10 Y:2015 | 10 | 2015 | ADD AREA LIGHTING SWITCHES | $1,177 | $940 | Not Implemented |
UK1514 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,139 | $896 | Implemented |
UK1514 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,011 | $742 | Not Implemented |
UK1514 # 13 Y:2015 | 13 | 2015 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $10,092 | $6,632 | Not Implemented |
UK1501 # 01 Y:2015 | 01 | 2015 | OPTIMIZE PLANT POWER FACTOR | $2,481 | $2,300 | Not Implemented |
UK1501 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,106 | $0 | Not Implemented |
UK1501 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,967 | $500 | Implemented |
UK1501 # 04 Y:2015 | 04 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,186 | $7,500 | Not Implemented |
UK1501 # 05 Y:2015 | 05 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $5,665 | $20,000 | Implemented |
UK1501 # 06 Y:2015 | 06 | 2015 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $49 | $100 | Not Implemented |