Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

252

matching recommendations
Reset
NAICS 336360 Motor Vehicle Seating and Interior Trim Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0510 # 01 Y:2015 01 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $65,610 $211,134 Not Implemented
WV0510 # 02 Y:2015 02 2015 INSULATE BARE EQUIPMENT $47,885 $8,730 Not Implemented
WV0510 # 03 Y:2015 03 2015 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $15,681 $1,000 Implemented
WV0510 # 04 Y:2015 04 2015 INSTALL OCCUPANCY SENSORS $9,890 $3,930 Implemented
UA0117 # 01 Y:2014 01 2014 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $116,327 $120 Not Implemented
UA0117 # 02 Y:2014 02 2014 RECOVER WASTE HEAT FROM EQUIPMENT $2,244 $3,515 Not Implemented
UA0117 # 03 Y:2014 03 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $14,760 $21,000 Implemented
UA0117 # 04 Y:2014 04 2014 INSTALL OCCUPANCY SENSORS $4,219 $1,139 Not Implemented
UA0117 # 05 Y:2014 05 2014 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,571 $7,675 Not Implemented
UA0117 # 06 Y:2014 06 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,971 $800 Not Implemented
UA0117 # 07 Y:2014 07 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,033 $1,900 Not Implemented
TT0128 # 01 Y:2014 01 2014 DISCONNECT BALLASTS $293 $0 Implemented
TT0128 # 02 Y:2014 02 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $125 $180 Implemented
TT0128 # 03 Y:2014 03 2014 INSTALL OCCUPANCY SENSORS $1,294 $1,550 Implemented
TT0128 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,860 $15,980 Implemented
TT0128 # 08 Y:2014 08 2014 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $15,563 $110,000 Not Implemented
TT0128 # 07 Y:2014 07 2014 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,636 $18,000 Not Implemented
TT0128 # 06 Y:2014 06 2014 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $598 $2,350 Implemented
TT0128 # 05 Y:2014 05 2014 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $14,016 $23,710 Implemented
UM0425 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $695 $308 Implemented
UM0425 # 02 Y:2013 02 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,480 $3,300 Implemented
UM0425 # 04 Y:2013 04 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,752 $5,000 Implemented
UM0425 # 03 Y:2013 03 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,115 $0 Implemented
UM0425 # 01 Y:2013 01 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $9,900 $13,000 Not Implemented
UA0103 # 01 Y:2013 01 2013 INSTALL TIMERS AND/OR THERMOSTATS $13,561 $150 Implemented