Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsNAICS | 336370 | Motor Vehicle Metal Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0889 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $1,290 | $1,400 | Not Implemented |
UD0889 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,401 | $9,000 | Not Implemented |
UD0889 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,219 | $7,254 | Not Implemented |
UD0889 # 05 Y:2013 | 05 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,355 | $2,000 | Not Implemented |
UD0889 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,551 | $3,500 | Not Implemented |
UD0889 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,100 | $0 | Implemented |
UD0889 # 02 Y:2013 | 02 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $654 | $460 | Implemented |
UD0889 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,448 | $1,000 | Not Implemented |
NC0489 # 02 Y:2013 | 02 | 2013 | USE PHOTOCELL CONTROLS | $3,519 | $1,000 | Not Implemented |
NC0489 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $808 | $100 | Implemented |
NC0489 # 05 Y:2013 | 05 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,517 | $50 | Not Implemented |
NC0489 # 04 Y:2013 | 04 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,150 | $1,500 | Not Implemented |
NC0489 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $1,103 | $971 | Not Implemented |
NC0489 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $156,661 | $530,811 | Implemented |
UM0424 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,312 | $750 | Implemented |
UM0424 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,204 | $1,000 | Implemented |
UM0424 # 03 Y:2013 | 03 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,141 | $600 | Not Implemented |
UM0424 # 04 Y:2013 | 04 | 2013 | USE MORE EFFICIENT ADHESIVE APPLICATORS | $44,144 | $40,000 | Not Implemented |
UM0424 # 05 Y:2013 | 05 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,695 | $1,600 | Implemented |