Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
122
matching recommendationsNAICS | 3364 | Aerospace Product and Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0977 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $871 | $1,272 | Not Implemented |
OK0977 # 05 Y:2017 | 05 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,443 | $2,300 | Not Implemented |
OK0977 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $16,088 | $1,209 | Not Implemented |
OK0977 # 07 Y:2017 | 07 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $67 | $208 | Not Implemented |
OK0977 # 08 Y:2017 | 08 | 2017 | COVER OPEN TANKS | $5,491 | $1,301 | Not Implemented |
OK0880 # 01 Y:2014 | 01 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $706 | $689 | Not Implemented |
OK0880 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $302 | $463 | Not Implemented |
OK0880 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,983 | $61,440 | Implemented |
OK0880 # 04 Y:2014 | 04 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $12,695 | $8,800 | Not Implemented |
OK0880 # 05 Y:2014 | 05 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $10,569 | $37,500 | Not Implemented |
OK0880 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $227 | $798 | Not Implemented |
OK0880 # 07 Y:2014 | 07 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,087 | $3,573 | Not Implemented |
OK0880 # 08 Y:2014 | 08 | 2014 | INSULATE BARE EQUIPMENT | $6,439 | $6,993 | Not Implemented |
OK0880 # 09 Y:2014 | 09 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,385 | $3,468 | Not Implemented |
OK0880 # 10 Y:2014 | 10 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $78 | $376 | Not Implemented |
OK0832 # 01 Y:2012 | 01 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,902 | $7,700 | Not Implemented |
OK0832 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $955 | $1,288 | Not Implemented |
OK0832 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $6,375 | Not Implemented |
OK0832 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $655 | $4,180 | Not Implemented |
OK0832 # 05 Y:2012 | 05 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,428 | $7,200 | Not Implemented |
OK0832 # 06 Y:2012 | 06 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,382 | $34,962 | Not Implemented |
OK0832 # 07 Y:2012 | 07 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,074 | $29,738 | Not Implemented |
OK0832 # 08 Y:2012 | 08 | 2012 | INSTALL SET-BACK TIMERS | $2,158 | $185 | Not Implemented |
OK0832 # 09 Y:2012 | 09 | 2012 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,579 | $1,170 | Implemented |
OK0832 # 10 Y:2012 | 10 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,669 | $696 | Not Implemented |