Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

36

matching recommendations
Reset
NAICS 336411 Aircraft Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0995 # 04 Y:2018 04 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $308 $0 Not Implemented
OK0995 # 02 Y:2018 02 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,425 $19,203 Implemented
OK0995 # 01 Y:2018 01 2018 OPTIMIZE PLANT POWER FACTOR $32,860 $45,285 Not Implemented
OK0995 # 05 Y:2018 05 2018 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,003 $2,512 Not Implemented
OK0995 # 03 Y:2018 03 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,644 $404 Implemented
OK0995 # 06 Y:2018 06 2018 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $444 $300 Implemented
OK0975 # 04 Y:2017 04 2017 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $2,312 $1,015 Not Implemented
OK0975 # 08 Y:2017 08 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,181 $0 Not Implemented
OK0975 # 03 Y:2017 03 2017 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $9,584 $9,120 Not Implemented
OK0975 # 02 Y:2017 02 2017 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $19,832 $46,320 Not Implemented
OK0975 # 01 Y:2017 01 2017 OPTIMIZE PLANT POWER FACTOR $25,427 $24,531 Not Implemented
OK0975 # 05 Y:2017 05 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $685 $0 Not Implemented
OK0975 # 06 Y:2017 06 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,429 $2,713 Not Implemented
OK0975 # 07 Y:2017 07 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,048 $438 Not Implemented
OK0887 # 01 Y:2014 01 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $36,397 $35,374 Implemented
OK0887 # 02 Y:2014 02 2014 INSTALL OCCUPANCY SENSORS $7,219 $3,969 Implemented
OK0887 # 03 Y:2014 03 2014 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $8,717 $3,613 Implemented
OK0887 # 04 Y:2014 04 2014 INSTALL OCCUPANCY SENSORS $1,814 $8,926 Implemented
OK0887 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,474 $11,975 Implemented
OK0887 # 06 Y:2014 06 2014 INSTALL TIMERS AND/OR THERMOSTATS $13,990 $0 Implemented
OK0887 # 07 Y:2014 07 2014 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,993 $0 Implemented
OK0847 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,698 $29,880 Implemented
OK0847 # 04 Y:2013 04 2013 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,473 $1,128 Implemented
OK0847 # 05 Y:2013 05 2013 USE RADIANT HEATER FOR SPOT HEATING $13,014 $32,500 Not Implemented
OK0847 # 06 Y:2013 06 2013 OPTIMIZE PLANT POWER FACTOR $12,719 $11,540 Not Implemented