Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
176
matching recommendationsNAICS | 3369 | Other Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0041 # 03 Y:2010 | 03 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $5,320 | $2,520 | Implemented |
UA0041 # 04 Y:2010 | 04 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $216,130 | $0 | Implemented |
UA0041 # 05 Y:2010 | 05 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $76,495 | $0 | Implemented |
UA0041 # 06 Y:2010 | 06 | 2010 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $21,020 | $19,015 | Not Implemented |
UA0041 # 07 Y:2010 | 07 | 2010 | INSULATE BARE EQUIPMENT | $1,020 | $2,450 | Implemented |
UA0041 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,050 | $2 | Implemented |
UA0041 # 09 Y:2010 | 09 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,310 | $22,000 | Not Implemented |
UA0041 # 10 Y:2010 | 10 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,050 | $7 | Not Implemented |
UA0041 # 11 Y:2010 | 11 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $5,765 | $675 | Implemented |
SD0392 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,246 | $20,870 | Not Implemented |
SD0392 # 02 Y:2007 | 02 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,991 | $7,991 | Not Implemented |
SD0392 # 03 Y:2007 | 03 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,417 | $17,500 | Not Implemented |
SD0392 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,970 | $0 | Not Implemented |
UD0754 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $135,639 | $80,000 | Implemented |
UD0754 # 02 Y:2007 | 02 | 2007 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $78,829 | $0 | Not Implemented |
UD0754 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $74,891 | $305,325 | Implemented |
UD0754 # 04 Y:2007 | 04 | 2007 | MINIMIZE WATER USAGE | $17,430 | $700 | Implemented |
UD0754 # 05 Y:2007 | 05 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,400 | $0 | Not Implemented |
UD0754 # 06 Y:2007 | 06 | 2007 | INSULATE BARE EQUIPMENT | $15,104 | $5,930 | Not Implemented |
UD0754 # 07 Y:2007 | 07 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,977 | $11,246 | Not Implemented |
UD0754 # 08 Y:2007 | 08 | 2007 | COVER OPEN TANKS | $2,295 | $355 | Not Implemented |
UD0754 # 09 Y:2007 | 09 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $825 | $64 | Not Implemented |
NC0338 # 01 Y:2006 | 01 | 2006 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $63,286 | $175,000 | Implemented |
NC0338 # 02 Y:2006 | 02 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $54,759 | $18,800 | Not Implemented |
NC0338 # 03 Y:2006 | 03 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,391 | $2,500 | Implemented |