Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsNAICS | 336992 | Military Armored Vehicle, Tank, and Tank Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0890 # 10 Y:2013 | 10 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $746,973 | $100,000 | Not Implemented |
UD0890 # 01 Y:2013 | 01 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $544,478 | $0 | Implemented |
UD0890 # 02 Y:2013 | 02 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,847 | $0 | Not Implemented |
UD0890 # 03 Y:2013 | 03 | 2013 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $37,340 | $0 | Implemented |
UD0890 # 04 Y:2013 | 04 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $136,711 | $0 | Implemented |
UD0890 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,587 | $19,427 | Not Implemented |
UD0890 # 06 Y:2013 | 06 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,216 | $0 | Implemented |
UD0890 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $37,438 | $6,000 | Implemented |
UD0890 # 08 Y:2013 | 08 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,203 | $0 | Implemented |
UD0890 # 09 Y:2013 | 09 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $176,886 | $101,000 | Not Implemented |
UM0375 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,802 | $5,500 | Implemented |
UM0375 # 04 Y:2010 | 04 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $27,796 | $140,490 | Implemented |
UM0375 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $7,646 | $4,232 | Implemented |
UM0375 # 02 Y:2010 | 02 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,709 | $4,000 | Implemented |
UM0375 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $126,231 | $236,764 | Implemented |
UA0041 # 11 Y:2010 | 11 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $5,765 | $675 | Implemented |
UA0041 # 10 Y:2010 | 10 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,050 | $7 | Not Implemented |
UA0041 # 09 Y:2010 | 09 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,310 | $22,000 | Not Implemented |
UA0041 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,050 | $2 | Implemented |
UA0041 # 07 Y:2010 | 07 | 2010 | INSULATE BARE EQUIPMENT | $1,020 | $2,450 | Implemented |
UA0041 # 06 Y:2010 | 06 | 2010 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $21,020 | $19,015 | Not Implemented |
UA0041 # 05 Y:2010 | 05 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $76,495 | $0 | Implemented |
UA0041 # 04 Y:2010 | 04 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $216,130 | $0 | Implemented |
UA0041 # 03 Y:2010 | 03 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $5,320 | $2,520 | Implemented |
UA0041 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $2,630 | $380 | Not Implemented |