Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsNAICS | 3371 | Household and Institutional Furniture and Kitchen Cabinet Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW2312 # 05 Y:2023 | 05 | 2023 | OPTIMIZE PLANT POWER FACTOR | $10,128 | $13,235 | Not Implemented |
UW2312 # 04 Y:2023 | 04 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $236,659 | $2,614,888 | Not Implemented |
UW2312 # 03 Y:2023 | 03 | 2023 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,841 | $1,520 | Not Implemented |
UW2312 # 02 Y:2023 | 02 | 2023 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,868 | $20 | Not Implemented |
UW2312 # 01 Y:2023 | 01 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,943 | $30,989 | Not Implemented |
UW0005 # 05 Y:2007 | 05 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,388 | $2,619 | Implemented |
UW0005 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $354 | $650 | Not Implemented |
UW0005 # 08 Y:2007 | 08 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,795 | $398 | Implemented |
UW0005 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,766 | $432 | Implemented |
UW0005 # 06 Y:2007 | 06 | 2007 | OPTIMIZE PLANT POWER FACTOR | $6,971 | $17,098 | Not Implemented |
UW0005 # 04 Y:2007 | 04 | 2007 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $8,530 | $1,852 | Not Implemented |
UW0005 # 03 Y:2007 | 03 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,246 | $1,162 | Implemented |
UW0005 # 02 Y:2007 | 02 | 2007 | REPOSITION OVEN WALLS TO REDUCE HEATED SPACE | $15,876 | $4,452 | Implemented |
UW0005 # 01 Y:2007 | 01 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,804 | $7,172 | Implemented |
OR0436 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,500 | $7,680 | Implemented |
OR0436 # 05 Y:2003 | 05 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $48,169 | $66,400 | Implemented |
OR0436 # 04 Y:2003 | 04 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $8,380 | $6,780 | Implemented |
OR0436 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,840 | $3,000 | Not Implemented |
OR0436 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,530 | $0 | Implemented |