Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsNAICS | 337124 | Metal Household Furniture Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0311 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,142 | $3,555 | Implemented |
NC0311 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,051 | $7,280 | Not Implemented |
NC0311 # 07 Y:2005 | 07 | 2005 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $242,500 | $150,000 | Not Implemented |
NC0311 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,158 | $100 | Implemented |
NC0311 # 02 Y:2005 | 02 | 2005 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $15,075 | $4,000 | Not Implemented |
NC0311 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,798 | $14,107 | Implemented |
OK0683 # 03 Y:2004 | 03 | 2004 | OPTIMIZE PLANT POWER FACTOR | $8,063 | $7,713 | Implemented |
OK0683 # 07 Y:2004 | 07 | 2004 | INSTALL SET-BACK TIMERS | $19,818 | $8,100 | Implemented |
OK0683 # 06 Y:2004 | 06 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,723 | $2,000 | Not Implemented |
OK0683 # 05 Y:2004 | 05 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,463 | $2,000 | Not Implemented |
OK0683 # 04 Y:2004 | 04 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,889 | $600 | Not Implemented |
OK0683 # 02 Y:2004 | 02 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,800 | $0 | Not Implemented |
OK0683 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,702 | $1,080 | Not Implemented |
LM0073 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,649 | $0 | Implemented |
LM0073 # 04 Y:2004 | 04 | 2004 | ADD AREA LIGHTING SWITCHES | $6,155 | $1,600 | Not Implemented |
LM0073 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,384 | $0 | Not Implemented |
LM0073 # 05 Y:2004 | 05 | 2004 | INSTALL SPECTRAL REFLECTORS / DELAMP | $784 | $0 | Implemented |
LM0073 # 06 Y:2004 | 06 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,570 | $1,093 | Implemented |
LM0073 # 07 Y:2004 | 07 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,911 | $3,520 | Not Implemented |
LM0073 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,302 | $10,000 | Not Implemented |
LM0073 # 09 Y:2004 | 09 | 2004 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $27,520 | $4,000 | Implemented |
LM0073 # 10 Y:2004 | 10 | 2004 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $207,176 | $0 | Not Implemented |
LM0073 # 11 Y:2004 | 11 | 2004 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $10,400 | $1,562 | Implemented |
LM0073 # 12 Y:2004 | 12 | 2004 | DEVELOP STANDARD OPERATING PROCEDURES | $33,857 | $9,860 | Not Implemented |
LM0073 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,682 | $1,300 | Implemented |