Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
50
matching recommendationsNAICS | 33721 | Office Furniture (including Fixtures) Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0759 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $664 | $500 | Implemented |
UD0759 # 07 Y:2007 | 07 | 2007 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $534 | $0 | Not Implemented |
UD0759 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $266 | $0 | Not Implemented |
UD0759 # 09 Y:2007 | 09 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $173 | $0 | Not Implemented |
WV0336 # 09 Y:2006 | 09 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $320 | $0 | Not Implemented |
WV0336 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $796 | $189 | Implemented |
WV0336 # 07 Y:2006 | 07 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $2,688 | $231 | Implemented |
WV0336 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,345 | $0 | Implemented |
WV0336 # 04 Y:2006 | 04 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,755 | $0 | Implemented |
WV0336 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,097 | $510 | Not Implemented |
WV0336 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,594 | $14,968 | Implemented |
WV0336 # 02 Y:2006 | 02 | 2006 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $14,092 | $25,000 | Not Implemented |
WV0336 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,454 | $1,333 | Implemented |
WV0334 # 08 Y:2006 | 08 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,543 | $650 | Implemented |
WV0334 # 09 Y:2006 | 09 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,275 | $2,748 | Implemented |
WV0334 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,226 | $0 | Implemented |
WV0334 # 11 Y:2006 | 11 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $874 | $145 | Implemented |
WV0334 # 12 Y:2006 | 12 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $401 | $170 | Implemented |
WV0334 # 01 Y:2006 | 01 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $50,392 | $80,000 | Not Implemented |
WV0334 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,971 | $13,343 | Implemented |
WV0334 # 03 Y:2006 | 03 | 2006 | OPTIMIZE PLANT POWER FACTOR | $20,449 | $12,020 | Implemented |
WV0334 # 04 Y:2006 | 04 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $11,461 | $648 | Implemented |
WV0334 # 05 Y:2006 | 05 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,398 | $350 | Implemented |
WV0334 # 06 Y:2006 | 06 | 2006 | REDUCE VENTILATION AIR | $3,560 | $892 | Implemented |
WV0334 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $2,103 | $473 | Implemented |