Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
194
matching recommendationsNAICS | 339 | Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0993 # 01 Y:2018 | 01 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $27,720 | $0 | Not Implemented |
UD0919 # 11 Y:2015 | 11 | 2015 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $242 | $700 | Not Implemented |
UD0919 # 13 Y:2015 | 13 | 2015 | CLEAN FOULING FROM WATER LINES REGULARLY | $5,080 | $2,750 | Not Implemented |
UD0919 # 12 Y:2015 | 12 | 2015 | MAKE A NEW BY-PRODUCT | $24,789 | $46,000 | Not Implemented |
UD0919 # 10 Y:2015 | 10 | 2015 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,652 | $5,000 | Not Implemented |
UD0919 # 09 Y:2015 | 09 | 2015 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $4,591 | $4,300 | Not Implemented |
UD0919 # 08 Y:2015 | 08 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,715 | $0 | Implemented |
UD0919 # 07 Y:2015 | 07 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $11,674 | $0 | Implemented |
UD0919 # 06 Y:2015 | 06 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,496 | $2,295 | Not Implemented |
UD0919 # 05 Y:2015 | 05 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $36,602 | $22,000 | Not Implemented |
UD0919 # 04 Y:2015 | 04 | 2015 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $29,266 | $9,200 | Implemented |
UD0919 # 03 Y:2015 | 03 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,936 | $50 | Implemented |
UD0919 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,792 | $0 | Implemented |
UD0919 # 01 Y:2015 | 01 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,757 | $0 | Implemented |
WV0485 # 01 Y:2014 | 01 | 2014 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,434 | $1,000 | Not Implemented |
WV0485 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,806 | $4,815 | Not Implemented |
WV0485 # 02 Y:2014 | 02 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $9,166 | $12,500 | Not Implemented |
WV0485 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $5,211 | $2,981 | Implemented |
WV0485 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,635 | $4,433 | Not Implemented |
WV0485 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $2,805 | $3,000 | Implemented |
WV0485 # 09 Y:2014 | 09 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,922 | $1,719 | Not Implemented |
WV0485 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,038 | $175 | Implemented |
WV0485 # 12 Y:2014 | 12 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $691 | $426 | Implemented |
WV0485 # 05 Y:2014 | 05 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,703 | $500 | Implemented |
WV0485 # 03 Y:2014 | 03 | 2014 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $5,371 | $10,550 | Not Implemented |