Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

46

matching recommendations
Reset
NAICS 339 Miscellaneous Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL2402 # 03 Y:2024 03 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $677 $0 n/a
UL2402 # 02 Y:2024 02 2024 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,889 $0 n/a
UL2402 # 01 Y:2024 01 2024 INSTALL SPECTRAL REFLECTORS / DELAMP $1,664 $1,130 n/a
UL2402 # 05 Y:2024 05 2024 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $176,163 $90,792 n/a
UL2402 # 04 Y:2024 04 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,801 $3,150 n/a
UL2402 # 06 Y:2024 06 2024 USE SOLAR HEAT TO MAKE ELECTRICTY $147,025 $1,560,993 n/a
UK1914 # 07 Y:2019 07 2019 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $150 $0 n/a
UK1914 # 10 Y:2019 10 2019 OPTIMIZE PLANT POWER FACTOR $14,446 $12,425 n/a
UK1914 # 09 Y:2019 09 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,556 $21,155 n/a
UK1914 # 05 Y:2019 05 2019 TURN OFF EQUIPMENT WHEN NOT IN USE $8,187 $0 n/a
UK1914 # 02 Y:2019 02 2019 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,217 $1,100 n/a
UK1914 # 04 Y:2019 04 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,233 $8,100 n/a
UK1914 # 06 Y:2019 06 2019 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $4,746 $1,370 n/a
UK1914 # 08 Y:2019 08 2019 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $145 $80 n/a
UK1914 # 01 Y:2019 01 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $642 $2,510 n/a
UK1914 # 03 Y:2019 03 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $394 $0 n/a
UK1709 # 13 Y:2017 13 2017 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $941 $1,492 Not Implemented
UK1709 # 01 Y:2017 01 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,732 $2,100 Not Implemented
UK1709 # 02 Y:2017 02 2017 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $1,143 $0 Not Implemented
UK1709 # 03 Y:2017 03 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,114 $453 Not Implemented
UK1709 # 04 Y:2017 04 2017 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $338 $0 Not Implemented
UK1709 # 05 Y:2017 05 2017 PREHEAT COMBUSTION AIR WITH WASTE HEAT $5,407 $3,304 Not Implemented
UK1709 # 06 Y:2017 06 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,910 $0 Not Implemented
UK1709 # 07 Y:2017 07 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,536 $0 Not Implemented
UK1709 # 08 Y:2017 08 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,908 $0 Not Implemented