Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsNAICS | 3391 | Medical Equipment and Supplies Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0710 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,710 | $340 | Implemented |
CO0710 # 01 Y:2015 | 01 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,950 | $3,660 | Not Implemented |
CO0710 # 04 Y:2015 | 04 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $370 | $1,170 | Not Implemented |
CO0710 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $470 | $60 | Implemented |
CO0686 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,120 | $4,630 | Not Implemented |
CO0686 # 05 Y:2014 | 05 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,080 | $1,500 | Implemented |
CO0686 # 04 Y:2014 | 04 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $6,330 | $27,820 | Implemented |
CO0686 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,690 | $0 | Implemented |
CO0686 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,170 | $6,690 | Not Implemented |
CO0686 # 01 Y:2014 | 01 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,160 | $8,890 | Not Implemented |
CO0581 # 02 Y:2006 | 02 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $430 | $430 | Not Implemented |
CO0581 # 06 Y:2006 | 06 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,580 | $18,370 | Not Implemented |
CO0581 # 05 Y:2006 | 05 | 2006 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $4,140 | $36,720 | Not Implemented |
CO0581 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,710 | $18,130 | Not Implemented |
CO0581 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,190 | $14,660 | Not Implemented |
CO0581 # 01 Y:2006 | 01 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,180 | $450 | Implemented |
CO0560 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,230 | $130 | Implemented |
CO0560 # 11 Y:2004 | 11 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,390 | $15,681 | Implemented |
CO0560 # 09 Y:2004 | 09 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,800 | $10,610 | Not Implemented |
CO0560 # 08 Y:2004 | 08 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $530 | $0 | Implemented |
CO0560 # 07 Y:2004 | 07 | 2004 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $650 | $0 | Not Implemented |
CO0560 # 06 Y:2004 | 06 | 2004 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $990 | $800 | Not Implemented |
CO0560 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,520 | $160 | Implemented |
CO0560 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,210 | $0 | Not Implemented |
CO0560 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $654 | $944 | Implemented |