Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,167

matching recommendations
Reset
NAICS 33911 Medical Equipment and Supplies Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0581 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,190 $14,660 Not Implemented
CO0581 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,710 $18,130 Not Implemented
CO0581 # 05 Y:2006 05 2006 USE SOLAR HEAT TO HEAT MAKE-UP AIR $4,140 $36,720 Not Implemented
CO0581 # 06 Y:2006 06 2006 USE SOLAR HEAT TO MAKE ELECTRICTY $1,580 $18,370 Not Implemented
SD0377 # 01 Y:2006 01 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $20,618 $0 Not Implemented
SD0377 # 02 Y:2006 02 2006 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $2,845 $0 Not Implemented
SD0377 # 03 Y:2006 03 2006 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,914 $0 Not Implemented
SD0377 # 04 Y:2006 04 2006 INSTALL OCCUPANCY SENSORS $1,461 $384 Not Implemented
SD0377 # 05 Y:2006 05 2006 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,088 $594 Not Implemented
SD0377 # 06 Y:2006 06 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $968 $0 Not Implemented
SD0377 # 07 Y:2006 07 2006 USE PHOTOCELL CONTROLS $771 $2,320 Not Implemented
SD0377 # 08 Y:2006 08 2006 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $375 $688 Not Implemented
BD0302 # 01 Y:2006 01 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,774 $0 Not Implemented
BD0302 # 02 Y:2006 02 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,381 $0 Implemented
BD0302 # 03 Y:2006 03 2006 USE RADIANT HEATER FOR SPOT HEATING $1,699 $5,000 Not Implemented
BD0302 # 04 Y:2006 04 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,130 $0 Implemented
BD0302 # 05 Y:2006 05 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $848 $260 Not Implemented
BD0302 # 06 Y:2006 06 2006 INSTALL OCCUPANCY SENSORS $835 $1,050 Not Implemented
BD0302 # 07 Y:2006 07 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1 $0 Not Implemented
BD0302 # 08 Y:2006 08 2006 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,195 $1,550 Not Implemented
BD0302 # 09 Y:2006 09 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $384 $0 Implemented
BD0302 # 10 Y:2006 10 2006 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $344 $500 Implemented
BD0302 # 11 Y:2006 11 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $304 $2,550 Not Implemented
BD0302 # 12 Y:2006 12 2006 MINIMIZE WATER USAGE $2,375 $1,725 Not Implemented
MA0589 # 01 Y:2006 01 2006 BURN A LESS EXPENSIVE GRADE OF FUEL $29,215 $95,420 Not Implemented