Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
332
matching recommendationsNAICS | 339113 | Surgical Appliance and Supplies Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0203 # 07 Y:2005 | 07 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,401 | $500 | Not Implemented |
LE0203 # 08 Y:2005 | 08 | 2005 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $864 | $0 | Not Implemented |
AM0463 # 01 Y:2004 | 01 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $23,300 | $19,700 | Implemented |
AM0463 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $18,200 | $16,600 | Implemented |
AM0463 # 03 Y:2004 | 03 | 2004 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $14,500 | $7,550 | Not Implemented |
AM0463 # 04 Y:2004 | 04 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,100 | $0 | Implemented |
AM0463 # 05 Y:2004 | 05 | 2004 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,475 | $0 | Implemented |
AM0463 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,470 | $20 | Not Implemented |
AM0463 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,450 | $730 | Implemented |
AM0463 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,030 | $400 | Implemented |
LE0156 # 01 Y:2003 | 01 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $1,112 | $870 | Implemented |
LE0156 # 02 Y:2003 | 02 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,320 | $750 | Not Implemented |
LE0156 # 03 Y:2003 | 03 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,466 | $0 | Not Implemented |
LE0156 # 04 Y:2003 | 04 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,340 | $0 | Implemented |
LE0156 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $1,413 | $0 | Implemented |
LE0156 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $844 | $0 | Not Implemented |
LE0156 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $239 | $600 | Implemented |
OK0654 # 01 Y:2003 | 01 | 2003 | INSTALL SET-BACK TIMERS | $6,206 | $744 | Not Implemented |
OK0654 # 02 Y:2003 | 02 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,461 | $5,880 | Not Implemented |
OK0654 # 03 Y:2003 | 03 | 2003 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,131 | $0 | Not Implemented |
OK0654 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $640 | Not Implemented |
OK0654 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $336 | $349 | Not Implemented |
OK0654 # 06 Y:2003 | 06 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $232,400 | $2,844 | Not Implemented |
OK0654 # 07 Y:2003 | 07 | 2003 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $1,040 | $165 | Not Implemented |
MA0526 # 01 Y:2003 | 01 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $29,601 | $51,300 | n/a |