Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,372
matching recommendationsNAICS | 3399 | Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0221 # 10 Y:2005 | 10 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $259 | $721 | Implemented |
SU0221 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $96 | $391 | Implemented |
WV0325 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $16,088 | $12,504 | Not Implemented |
WV0325 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $10,956 | $11,550 | Not Implemented |
WV0325 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,144 | $662 | Implemented |
WV0325 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,050 | $653 | Implemented |
WV0325 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,009 | $0 | Implemented |
WV0325 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,529 | $408 | Not Implemented |
WV0325 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $2,990 | $257 | Implemented |
WV0325 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,637 | $420 | Implemented |
WV0325 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $851 | $426 | Implemented |
WV0325 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $832 | $2,612 | Implemented |
WV0325 # 11 Y:2005 | 11 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $775 | $521 | Not Implemented |
WV0325 # 12 Y:2005 | 12 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $756 | $260 | Implemented |
WV0325 # 13 Y:2005 | 13 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $416 | $276 | Not Implemented |
MS0281 # 01 Y:2005 | 01 | 2005 | BURN A LESS EXPENSIVE GRADE OF FUEL | $79,041 | $295,888 | Not Implemented |
MS0281 # 02 Y:2005 | 02 | 2005 | COMBINE UTILITY METERS | $12,247 | $0 | Not Implemented |
MS0281 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $2,683 | $1,211 | Not Implemented |
MS0281 # 04 Y:2005 | 04 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $2,668 | $800 | Not Implemented |
MS0281 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,603 | $2,508 | Not Implemented |
MS0281 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $1,380 | $243 | Not Implemented |
MS0281 # 07 Y:2005 | 07 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,009 | $855 | Implemented |
MS0281 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $901 | $176 | Implemented |
MS0281 # 09 Y:2005 | 09 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $809 | $0 | Implemented |
MS0281 # 10 Y:2005 | 10 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $782 | $405 | Implemented |