Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsNAICS | 33999 | All Other Miscellaneous Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0748 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $303 | $108 | Implemented |
UD0748 # 04 Y:2006 | 04 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,988 | $2,960 | Not Implemented |
UD0748 # 03 Y:2006 | 03 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,200 | $840 | Implemented |
UD0748 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,546 | $0 | Implemented |
UD0748 # 01 Y:2006 | 01 | 2006 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $432,000 | $143,750 | Not Implemented |
MS0297 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,825 | $225 | Implemented |
MS0297 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,548 | $26,994 | Not Implemented |
MS0297 # 01 Y:2006 | 01 | 2006 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $45,413 | $160,000 | Not Implemented |
MS0297 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,005 | $7,451 | Not Implemented |
LM0112 # 02 Y:2006 | 02 | 2006 | ADJUST VENTS TO MINIMIZE ENERGY USE | $19,700 | $0 | Not Implemented |
LM0112 # 06 Y:2006 | 06 | 2006 | ADD ADDITIONAL PRODUCTION SHIFT | $1,348 | $0 | Implemented |
LM0112 # 05 Y:2006 | 05 | 2006 | MODIFY STARTUP/SHUTDOWN TIMES | $10,000 | $0 | Not Implemented |
LM0112 # 04 Y:2006 | 04 | 2006 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $433,948 | $1,000 | Not Implemented |
LM0112 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,130 | $8,728 | Implemented |
LM0112 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $615 | $200 | Implemented |
UD0735 # 06 Y:2006 | 06 | 2006 | DISCONNECT BALLASTS | $9,527 | $1,440 | Implemented |
UD0735 # 03 Y:2006 | 03 | 2006 | RECOVER MECHANICAL ENERGY | $33,450 | $32 | Implemented |
UD0735 # 01 Y:2006 | 01 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $212,325 | $9,000 | Implemented |
UD0735 # 02 Y:2006 | 02 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $36,368 | $5,000 | Not Implemented |
UD0735 # 05 Y:2006 | 05 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $14,908 | $5,056 | Not Implemented |
UD0735 # 04 Y:2006 | 04 | 2006 | REDUCE VENTILATION AIR | $38,385 | $0 | Not Implemented |
UD0735 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $5,203 | $21,789 | Implemented |
UD0735 # 08 Y:2006 | 08 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,043 | $9,000 | Not Implemented |
UD0735 # 10 Y:2006 | 10 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,932 | $0 | Not Implemented |
UD0735 # 09 Y:2006 | 09 | 2006 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $3,767 | $700 | Not Implemented |