Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

55

matching recommendations
Reset
NAICS 339995 Burial Casket Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0735 # 02 Y:2006 02 2006 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $36,368 $5,000 Not Implemented
UD0735 # 15 Y:2006 15 2006 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $376 $214 Not Implemented
UD0735 # 14 Y:2006 14 2006 USE PHOTOCELL CONTROLS $733 $308 Implemented
UD0735 # 13 Y:2006 13 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,293 $0 Not Implemented
UD0735 # 12 Y:2006 12 2006 RECOVER AND REUSE COOLING WATER $2,635 $1,000 Not Implemented
UD0735 # 11 Y:2006 11 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,665 $0 Implemented
UD0735 # 10 Y:2006 10 2006 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,932 $0 Not Implemented
UD0735 # 08 Y:2006 08 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,043 $9,000 Not Implemented
UD0735 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $5,203 $21,789 Implemented
UD0735 # 06 Y:2006 06 2006 DISCONNECT BALLASTS $9,527 $1,440 Implemented
UD0735 # 05 Y:2006 05 2006 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $14,908 $5,056 Not Implemented
UD0735 # 04 Y:2006 04 2006 REDUCE VENTILATION AIR $38,385 $0 Not Implemented
UD0735 # 03 Y:2006 03 2006 RECOVER MECHANICAL ENERGY $33,450 $32 Implemented
UD0735 # 01 Y:2006 01 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $212,325 $9,000 Implemented
UD0735 # 09 Y:2006 09 2006 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $3,767 $700 Not Implemented
WV0307 # 15 Y:2004 15 2004 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $75 $0 Not Implemented
WV0307 # 10 Y:2004 10 2004 DEVELOP A REPAIR/REPLACE POLICY $1,513 $271 Implemented
WV0307 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,177 $210 Implemented
WV0307 # 08 Y:2004 08 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,767 $53 Implemented
WV0307 # 07 Y:2004 07 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,956 $1,260 Not Implemented
WV0307 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,120 $600 Not Implemented
WV0307 # 05 Y:2004 05 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,255 $1,505 Not Implemented
WV0307 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,891 $4,040 Not Implemented
WV0307 # 03 Y:2004 03 2004 ISOLATE HOT OR COLD EQUIPMENT $3,113 $755 Implemented
WV0307 # 02 Y:2004 02 2004 MINIMIZE WATER USAGE $9,168 $7,800 Not Implemented