Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
229
matching recommendationsNAICS | 511110 | Newspaper Publishers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0181 # 03 Y:2004 | 03 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,560 | $0 | Not Implemented |
SU0181 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,821 | $264 | Not Implemented |
SU0181 # 05 Y:2004 | 05 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $15,188 | $1,545 | Implemented |
SU0181 # 06 Y:2004 | 06 | 2004 | USE SYNTHETIC LUBRICANT | $7,821 | $1,000 | Not Implemented |
SU0181 # 07 Y:2004 | 07 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,229 | $368 | Implemented |
SU0181 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,202 | $6,469 | Not Implemented |
SU0179 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,807 | $0 | Not Implemented |
SU0179 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $543 | $0 | Not Implemented |
SU0179 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,108 | $6,327 | Not Implemented |
SU0179 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,671 | $2,665 | Not Implemented |
SU0179 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,469 | $6,227 | Not Implemented |
SU0167 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $839 | $0 | Implemented |
SU0167 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $633 | $0 | Not Implemented |
SU0167 # 03 Y:2003 | 03 | 2003 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $8,152 | $147 | Not Implemented |
SU0167 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,750 | $214 | Not Implemented |
SU0167 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $603 | $116 | Not Implemented |
SU0167 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,319 | $5,775 | Not Implemented |
SF0263 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,812 | $1,128 | Not Implemented |
SF0263 # 02 Y:2003 | 02 | 2003 | USE PHOTOCELL CONTROLS | $766 | $720 | Not Implemented |
SF0263 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $2,695 | $4,480 | Not Implemented |
SF0263 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,766 | $29,810 | Not Implemented |
SF0263 # 05 Y:2003 | 05 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,730 | $20,475 | Not Implemented |
SF0263 # 06 Y:2003 | 06 | 2003 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $687 | $0 | Not Implemented |
SF0263 # 07 Y:2003 | 07 | 2003 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,360 | $0 | Not Implemented |
SF0255 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,228 | $140 | Implemented |