Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
482
matching recommendationsNAICS | 611 | Educational Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0253 # 02 Y:2024 | 02 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,113 | $26,430 | Implemented |
UU0253 # 03 Y:2024 | 03 | 2024 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $22,211 | $18,400 | Implemented |
UU0253 # 04 Y:2024 | 04 | 2024 | OPTIMIZE PLANT POWER FACTOR | $717 | $2,200 | Implemented |
UU0253 # 05 Y:2024 | 05 | 2024 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $150 | $450 | Not Implemented |
AM0919 # 01 Y:2024 | 01 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,964 | $20,366 | n/a |
AM0919 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $19,780 | $468,000 | n/a |
AM0919 # 03 Y:2024 | 03 | 2024 | REDUCE FLUID FLOW RATES | $1,498 | $3,000 | n/a |
AM0919 # 04 Y:2024 | 04 | 2024 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,503 | $2,500 | n/a |
AM0919 # 05 Y:2024 | 05 | 2024 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $317 | $1,000 | n/a |
AM0918 # 01 Y:2024 | 01 | 2024 | REDUCE FLUID FLOW RATES | $1,310 | $3,000 | n/a |
AM0918 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $25,377 | $489,840 | n/a |
AM0918 # 03 Y:2024 | 03 | 2024 | REPAIR FAULTY LOUVERS AND DAMPERS | $412 | $3,000 | n/a |
AM0918 # 04 Y:2024 | 04 | 2024 | INSTALL OCCUPANCY SENSORS | $2,244 | $1,215 | n/a |
AM0918 # 05 Y:2024 | 05 | 2024 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,601 | $3,000 | n/a |
AM0917 # 01 Y:2024 | 01 | 2024 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $362 | $3,000 | n/a |
AM0917 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $21,840 | $468,000 | n/a |
AM0917 # 03 Y:2024 | 03 | 2024 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $21 | $300 | n/a |
AM0917 # 04 Y:2024 | 04 | 2024 | INSTALL OCCUPANCY SENSORS | $77 | $1,470 | n/a |
CI0028 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $117,628 | $341,230 | n/a |
CI0028 # 02 Y:2024 | 02 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $43,415 | $1,900 | n/a |
CI0028 # 03 Y:2024 | 03 | 2024 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $14,256 | $92,800 | n/a |
CI0028 # 04 Y:2024 | 04 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,253 | $80,000 | n/a |
CI0028 # 05 Y:2024 | 05 | 2024 | INSTALL OCCUPANCY SENSORS | $5,668 | $5,200 | n/a |
CI0028 # 06 Y:2024 | 06 | 2024 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $5,530 | $11,000 | n/a |
CI0028 # 07 Y:2024 | 07 | 2024 | MINIMIZE WATER USAGE | $5,321 | $22,000 | n/a |