Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
48
matching recommendationsNAICS | 622 | Hospitals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0198 # 01 Y:2022 | 01 | 2022 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $13,222 | $12,000 | Implemented |
MI0340 # 06 Y:2018 | 06 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,618 | $12,938 | Implemented |
MI0340 # 04 Y:2018 | 04 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $64,892 | $24,640 | Implemented |
MI0340 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68,630 | $44,639 | Implemented |
UA0166 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,666 | $38,071 | Implemented |
UA0166 # 06 Y:2016 | 06 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $617 | $200 | Implemented |
UA0166 # 05 Y:2016 | 05 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,707 | $120 | Implemented |
UA0166 # 03 Y:2016 | 03 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $26,248 | $80 | Implemented |
UA0166 # 02 Y:2016 | 02 | 2016 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $25,491 | $80 | Implemented |
UA0166 # 08 Y:2016 | 08 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,753 | $1,050 | Implemented |
IA0545 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,509 | $115,341 | Implemented |
IA0545 # 01 Y:2015 | 01 | 2015 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $37,834 | $27,000 | Implemented |
IA0545 # 04 Y:2015 | 04 | 2015 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $5,172 | $620 | Implemented |
IA0545 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,267 | $4,620 | Implemented |
IA0545 # 06 Y:2015 | 06 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $231 | $292 | Implemented |
OK0869 # 04 Y:2013 | 04 | 2013 | KEEP BOILER TUBES CLEAN | $9,106 | $3,420 | Implemented |
OK0869 # 06 Y:2013 | 06 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,056 | $2,140 | Implemented |
OK0869 # 09 Y:2013 | 09 | 2013 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $38,010 | $23,834 | Implemented |
OK0869 # 13 Y:2013 | 13 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,890 | $21,025 | Implemented |
OK0837 # 02 Y:2012 | 02 | 2012 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $17,278 | $4,230 | Implemented |
OK0837 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $670 | $4,525 | Implemented |
OK0837 # 08 Y:2012 | 08 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,797 | $18,000 | Implemented |
OK0837 # 10 Y:2012 | 10 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,778 | $1,400 | Implemented |