Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
189
matching recommendationsSIC | 14 | Nonmetallic Minerals, Except Fuels |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0046 # 03 Y:2002 | 03 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,162 | $1,016 | Implemented |
MI0046 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,120 | $1,068 | Implemented |
MI0046 # 05 Y:2002 | 05 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $7,998 | $8 | Implemented |
MI0040 # 01 Y:2002 | 01 | 2002 | INSTALL BACK-UP EQUIPMENT | $16,380 | $17,500 | Implemented |
MI0040 # 02 Y:2002 | 02 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $86,400 | $6,084 | Implemented |
MI0040 # 03 Y:2002 | 03 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $25,467 | $18,252 | Implemented |
MI0040 # 04 Y:2002 | 04 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,252 | $30 | Not Implemented |
MI0040 # 05 Y:2002 | 05 | 2002 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $50,534 | $52,260 | Not Implemented |
MI0041 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,947 | $1,040 | Not Implemented |
MI0041 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $415,200 | $783,200 | Not Implemented |
MI0041 # 03 Y:2002 | 03 | 2002 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $46,426 | $44,225 | Not Implemented |
MI0041 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $207,600 | $391,350 | Not Implemented |
MI0041 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $46,505 | $41,115 | Not Implemented |
MI0030 # 01 Y:2002 | 01 | 2002 | CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES | $113,786 | $15 | Implemented |
MI0030 # 02 Y:2002 | 02 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $70,800 | $7,140 | Implemented |
MI0030 # 03 Y:2002 | 03 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,323 | $962 | Not Implemented |
MI0030 # 04 Y:2002 | 04 | 2002 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $10,368 | $4,260 | Not Implemented |
MI0030 # 05 Y:2002 | 05 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,370 | $2,730 | Not Implemented |
AM0411 # 01 Y:2002 | 01 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,800 | $0 | Implemented |
AM0411 # 02 Y:2002 | 02 | 2002 | PAY UTILITY BILLS ON TIME | $6,350 | $0 | Implemented |
AM0411 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,140 | $33,400 | Implemented |
AM0411 # 04 Y:2002 | 04 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,680 | $340 | Implemented |
AM0411 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,190 | $560 | Implemented |
AM0411 # 06 Y:2002 | 06 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,440 | $600 | Implemented |
AM0411 # 07 Y:2002 | 07 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,140 | $0 | Implemented |