IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

285

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0136 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,212 $600 n/a
ME0136 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,058 $400 n/a
ME0136 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $600 $50 n/a
ME0136 # 04 Y:1994 04 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,772 $20 n/a
ME0136 # 05 Y:1994 05 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,959 $2,584 n/a
ME0136 # 06 Y:1994 06 1994 INSULATE BARE EQUIPMENT $520 $130 n/a
ME0136 # 07 Y:1994 07 1994 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $1,300 $900 n/a
ME0136 # 08 Y:1994 08 1994 REPAIR OR REPLACE STEAM TRAPS $2,150 $300 n/a
ME0130 # 01 Y:1994 01 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,418 $150 Implemented
ME0130 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $20,697 $40,000 Not Implemented
ME0130 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $899 $1,300 Not Implemented
ME0130 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,470 $8,260 Not Implemented
ME0130 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,530 $15,100 Not Implemented
ME0119 # 01 Y:1994 01 1994 MINIMIZE WATER USAGE $21,700 $12,150 Implemented
ME0119 # 02 Y:1994 02 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $403 $600 Not Implemented
ME0119 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,555 $100 Not Implemented
ME0119 # 04 Y:1994 04 1994 OPTIMIZE PLANT POWER FACTOR $1,327 $2,280 Not Implemented
ME0119 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,504 $4,415 Not Implemented
ME0109 # 01 Y:1993 01 1993 OPTIMIZE PLANT POWER FACTOR $14,260 $2,500 Not Implemented
ME0109 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,215 $4,300 Not Implemented
ME0109 # 03 Y:1993 03 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,548 $4,674 Implemented
ME0109 # 04 Y:1993 04 1993 RECOVER WASTE HEAT FROM EQUIPMENT $5,450 $9,000 Not Implemented
MA0248 # 01 Y:1992 01 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,681 $30,404 Not Implemented
MA0248 # 02 Y:1992 02 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,051 $10 Implemented
MA0248 # 03 Y:1992 03 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,622 $1,872 Implemented