Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
473
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0186 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,734 | $7,000 | Implemented |
AS0186 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,738 | $0 | Implemented |
AS0186 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,675 | $2,086 | Implemented |
AS0186 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $712 | $525 | Implemented |
AS0186 # 07 Y:1996 | 07 | 1996 | METER WASTE WATER | $8,798 | $5,000 | Implemented |
AS0186 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $465 | $0 | Implemented |
AS0185 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,866 | $0 | Implemented |
AS0185 # 02 Y:1996 | 02 | 1996 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,309 | $255 | Implemented |
AS0185 # 03 Y:1996 | 03 | 1996 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $416 | $120 | Implemented |
AS0185 # 04 Y:1996 | 04 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $882 | $100 | Implemented |
AS0185 # 05 Y:1996 | 05 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,378 | $1,938 | Implemented |
AS0185 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $688 | $1,400 | Not Implemented |
AS0185 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $1,230 | $1,050 | Not Implemented |
AS0185 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $103 | $128 | Implemented |
AS0185 # 09 Y:1996 | 09 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $590 | $1,236 | Not Implemented |
AS0185 # 10 Y:1996 | 10 | 1996 | IMPROVE HANDLING PRACTICES | $3,909 | $1,500 | Implemented |
AS0180 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,604 | $0 | Not Implemented |
AS0180 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,978 | $14,977 | Implemented |
AS0180 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $2,295 | $1,350 | Not Implemented |
AS0180 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,307 | $9,177 | Not Implemented |
AS0180 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,240 | $5,343 | Not Implemented |
AS0180 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $63,244 | $50,000 | Implemented |
AS0180 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,003 | $0 | Not Implemented |
AS0180 # 08 Y:1996 | 08 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $391 | $320 | Not Implemented |
AS0180 # 09 Y:1996 | 09 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,648 | $30 | Implemented |