IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

529

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0247 # 02 Y:1988 02 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,591 $0 Implemented
KU0247 # 03 Y:1988 03 1988 INSTALL TURBULATORS $1,010 $350 Implemented
KU0247 # 04 Y:1988 04 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,305 $0 Implemented
KU0247 # 05 Y:1988 05 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $288 $0 Implemented
KU0247 # 06 Y:1988 06 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $331 $55 Not Implemented
KU0247 # 07 Y:1988 07 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $390 $705 Implemented
KU0217 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,663 $35,314 Not Implemented
KU0217 # 02 Y:1987 02 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,162 $0 Implemented
KU0217 # 03 Y:1987 03 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,090 $8,000 Not Implemented
KU0217 # 04 Y:1987 04 1987 INSTALL AUTOMATIC STACK DAMPER $5,647 $700 Not Implemented
KU0217 # 05 Y:1987 05 1987 INSTALL TURBULATORS $8,520 $6,627 Not Implemented
KU0217 # 06 Y:1987 06 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $549 $500 Implemented
KU0217 # 07 Y:1987 07 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,186 $4,170 Implemented
KU0217 # 08 Y:1987 08 1987 IMPROVE LUBRICATION PRACTICES $1,376 $700 Not Implemented
KU0217 # 09 Y:1987 09 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,661 $300 Implemented
KU0217 # 10 Y:1987 10 1987 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $19,971 $15,800 Not Implemented
KU0216 # 01 Y:1987 01 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $21,533 $20,000 Implemented
KU0216 # 02 Y:1987 02 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,014 $15,000 Not Implemented
KU0216 # 03 Y:1987 03 1987 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $6,934 $9,000 Not Implemented
KU0216 # 04 Y:1987 04 1987 INSTALL SET-BACK TIMERS $2,429 $683 Implemented
KU0216 # 05 Y:1987 05 1987 IMPROVE LUBRICATION PRACTICES $2,386 $2,250 Implemented
KU0216 # 06 Y:1987 06 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,562 $0 Implemented
KU0216 # 07 Y:1987 07 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,128 $200 Not Implemented
KU0183 # 01 Y:1986 01 1986 INSTALL SET-BACK TIMERS $4,326 $4,279 Implemented
KU0183 # 02 Y:1986 02 1986 RECOVER WASTE HEAT FROM EQUIPMENT $4,048 $6,000 Not Implemented