Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0508 # 06 Y:2015 06 2015 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $10,108 $7,873 Not Implemented
WV0508 # 09 Y:2015 09 2015 ISOLATE HOT OR COLD EQUIPMENT $3,639 $5,172 Not Implemented
WV0508 # 04 Y:2015 04 2015 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $14,278 $1,000 Implemented
WV0260 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $534 $0 Implemented
WV0260 # 14 Y:2003 14 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,307 $1,855 Not Implemented
WV0260 # 13 Y:2003 13 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $298 $40 Implemented
WV0260 # 12 Y:2003 12 2003 REPAIR AND ELIMINATE STEAM LEAKS $411 $1,000 Implemented
WV0260 # 11 Y:2003 11 2003 MINIMIZE WATER USAGE $26,493 $6,000 Not Implemented
WV0260 # 10 Y:2003 10 2003 REDUCE EXCESS STEAM BLEEDING $15,707 $60,000 Not Implemented
WV0260 # 09 Y:2003 09 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,444 $130 Implemented
WV0260 # 08 Y:2003 08 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $175 $0 Implemented
WV0260 # 07 Y:2003 07 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,720 $400 Implemented
WV0260 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,293 $4,594 Implemented
WV0260 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $597 $52 Implemented
WV0260 # 03 Y:2003 03 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $456 $250 Not Implemented
WV0260 # 02 Y:2003 02 2003 RECOVER WASTE HEAT FROM EQUIPMENT $1,475 $198 Not Implemented
WV0260 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $876 $130 Implemented
WV0215 # 05 Y:2001 05 2001 USE OPTIMUM THICKNESS INSULATION $1,387 $585 Implemented
WV0215 # 11 Y:2001 11 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $20,000 $12,000 Not Implemented
WV0215 # 03 Y:2001 03 2001 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,956 $1,278 Not Implemented
WV0215 # 04 Y:2001 04 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $92 $122 Not Implemented
WV0215 # 08 Y:2001 08 2001 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $97 $780 Implemented
WV0215 # 07 Y:2001 07 2001 INSTALL OCCUPANCY SENSORS $663 $150 Not Implemented
WV0215 # 02 Y:2001 02 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $93 $300 Implemented
WV0215 # 01 Y:2001 01 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $406 $52 Implemented