Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,335

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0482 # 05 Y:2005 05 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $640 $0 Implemented
AM0482 # 06 Y:2005 06 2005 INSULATE BARE EQUIPMENT $280 $50 Not Implemented
AM0482 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $605 $350 Implemented
TA0087 # 01 Y:2004 01 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $25,212 $8,570 Implemented
TA0087 # 02 Y:2004 02 2004 USE MINIMUM STEAM OPERATING PRESSURE $6,220 $0 Implemented
TA0087 # 03 Y:2004 03 2004 REPAIR AND ELIMINATE STEAM LEAKS $4,750 $1,125 Implemented
TA0087 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,391 $375 Implemented
TA0087 # 05 Y:2004 05 2004 USE MINIMUM STEAM OPERATING PRESSURE $3,275 $0 Implemented
TA0087 # 06 Y:2004 06 2004 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,900 $0 Not Implemented
TA0087 # 07 Y:2004 07 2004 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,340 $0 Implemented
TA0087 # 08 Y:2004 08 2004 INSULATE BARE EQUIPMENT $980 $200 Not Implemented
AM0472 # 01 Y:2004 01 2004 REPAIR OR REPLACE STEAM TRAPS $6,580 $590 Implemented
AM0472 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $6,640 $720 Implemented
AM0472 # 03 Y:2004 03 2004 USE SYNTHETIC LUBRICANT $2,630 $0 Not Implemented
AM0472 # 04 Y:2004 04 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $950 $290 Implemented
AM0472 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,000 $200 Implemented
AM0472 # 06 Y:2004 06 2004 INSTALL SKYLIGHTS $920 $0 Implemented
AM0471 # 01 Y:2004 01 2004 REPAIR OR REPLACE STEAM TRAPS $7,600 $930 Implemented
AM0471 # 02 Y:2004 02 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $6,640 $4,600 Implemented
AM0471 # 03 Y:2004 03 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $6,020 $270 Implemented
AM0471 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,450 $400 Implemented
AM0471 # 05 Y:2004 05 2004 USE SYNTHETIC LUBRICANT $1,920 $0 Implemented
AM0471 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $1,110 $170 Implemented
AM0471 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $230 $630 Implemented
AM0458 # 01 Y:2004 01 2004 OPTIMIZE PLANT POWER FACTOR $7,070 $15,675 Implemented