Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
575
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0311 # 04 Y:1998 | 04 | 1998 | USE PHOTOCELL CONTROLS | $11,300 | $340 | Implemented |
AM0311 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $2,785 | $0 | Not Implemented |
AM0311 # 06 Y:1998 | 06 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $2,170 | $0 | Implemented |
AM0311 # 07 Y:1998 | 07 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,620 | $1,010 | Implemented |
AM0311 # 08 Y:1998 | 08 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,500 | $2,100 | Implemented |
AM0311 # 09 Y:1998 | 09 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,400 | $0 | Not Implemented |
AM0311 # 10 Y:1998 | 10 | 1998 | $1,105 | $1,205 | Implemented | |
AM0311 # 11 Y:1998 | 11 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $290 | $93 | Not Implemented |
AM0311 # 12 Y:1998 | 12 | 1998 | INSTALL OCCUPANCY SENSORS | $250 | $485 | Not Implemented |
DS0101 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,339 | $10,895 | Not Implemented |
DS0101 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,905 | $1,750 | Not Implemented |
DS0101 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,424 | $820 | Not Implemented |
DS0101 # 04 Y:1998 | 04 | 1998 | MINIMIZE WATER USAGE | $2,739 | $0 | Not Implemented |
DS0101 # 05 Y:1998 | 05 | 1998 | MINIMIZE WATER USAGE | $5,125 | $-6,000 | Not Implemented |
DS0101 # 06 Y:1998 | 06 | 1998 | USE MECHANICAL STRIPPING METHODS | $675 | $2,295 | Not Implemented |
OR0311 # 01 Y:1998 | 01 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $112,722 | $650,500 | Not Implemented |
OR0311 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM THICKNESS INSULATION | $1,740 | $4,421 | Not Implemented |
OR0311 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $8,062 | $21,202 | Not Implemented |
OR0311 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,341 | $20,064 | Implemented |
OR0311 # 05 Y:1998 | 05 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,035 | $0 | Implemented |
OR0311 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,008 | $1,514 | Not Implemented |
OR0311 # 07 Y:1998 | 07 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $273 | $0 | Implemented |
OR0311 # 08 Y:1998 | 08 | 1998 | KEEP BOILER TUBES CLEAN | $1,431 | $1,500 | Not Implemented |
OR0311 # 09 Y:1998 | 09 | 1998 | MINIMIZE WATER USAGE | $1,020 | $0 | Not Implemented |
OR0311 # 10 Y:1998 | 10 | 1998 | MINIMIZE WATER USAGE | $275 | $0 | Not Implemented |