Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

825

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0312 # 04 Y:1990 04 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $61 $51 Not Implemented
OK0312 # 05 Y:1990 05 1990 IMPROVE LUBRICATION PRACTICES $69 $0 Implemented
OK0301 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,177 $650 Not Implemented
OK0301 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,279 $823 Implemented
OK0301 # 03 Y:1989 03 1989 OPTIMIZE PLANT POWER FACTOR $3,131 $6,000 Not Implemented
OK0301 # 04 Y:1989 04 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,277 $1,500 Implemented
OK0301 # 05 Y:1989 05 1989 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $4,774 $1,000 Not Implemented
OK0303 # 01 Y:1990 01 1990 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $132,453 $678,000 Not Implemented
OK0303 # 02 Y:1990 02 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,621 $9,954 Implemented
OK0303 # 03 Y:1990 03 1990 IMPROVE LUBRICATION PRACTICES $20,940 $0 Implemented
OK0303 # 04 Y:1990 04 1990 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $8,837 $2,075 Not Implemented
OK0297 # 01 Y:1989 01 1989 RECOVER WASTE HEAT FROM EQUIPMENT $2,160 $5,523 Not Implemented
OK0297 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,738 $1,478 Implemented
OK0297 # 03 Y:1989 03 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $233 $123 Implemented
OK0297 # 04 Y:1989 04 1989 OPTIMIZE PLANT POWER FACTOR $1,607 $2,500 Not Implemented
OK0297 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,788 $0 Implemented
OK0297 # 06 Y:1989 06 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $1,017 $2,289 Implemented
OK0292 # 01 Y:1989 01 1989 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,836 $4,300 Not Implemented
OK0292 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,733 $1,674 Not Implemented
OK0292 # 03 Y:1989 03 1989 RECOVER WASTE HEAT FROM EQUIPMENT $6,776 $12,000 Implemented
OK0289 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $658 $239 Implemented
OK0289 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,469 $719 Implemented
OK0289 # 03 Y:1989 03 1989 INSTALL TURBULATORS $632 $1,350 Implemented
OK0289 # 04 Y:1989 04 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $114 $135 Not Implemented
OK0289 # 05 Y:1989 05 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $81 $129 Not Implemented