Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
825
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0937 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,667 | $5,324 | Implemented |
OK0937 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,346 | $88,560 | Implemented |
OK0937 # 04 Y:2016 | 04 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,363 | $15,376 | Not Implemented |
OK0937 # 06 Y:2016 | 06 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,197 | $2,060 | Not Implemented |
OK0937 # 05 Y:2016 | 05 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,445 | $12,000 | Implemented |
OK0937 # 09 Y:2016 | 09 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,032 | $132,000 | Not Implemented |
OK0937 # 07 Y:2016 | 07 | 2016 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $74,720 | $594,190 | Not Implemented |
OK0912 # 05 Y:2015 | 05 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $34,469 | $69,120 | Not Implemented |
OK0912 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,007 | $1,150 | Implemented |
OK0912 # 02 Y:2015 | 02 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,191 | $8,250 | Implemented |
OK0912 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $699 | $1,752 | Implemented |
OK0912 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $710 | $806 | Not Implemented |
OK0912 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,077 | $10,897 | Implemented |
OK0912 # 07 Y:2015 | 07 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $421 | $1,460 | Not Implemented |
OK0912 # 09 Y:2015 | 09 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,274 | $460 | Implemented |
OK0912 # 13 Y:2015 | 13 | 2015 | INSULATE BARE EQUIPMENT | $18,908 | $74,880 | Not Implemented |
OK0912 # 12 Y:2015 | 12 | 2015 | OPTIMIZE PLANT POWER FACTOR | $7,346 | $12,507 | Not Implemented |
OK0912 # 11 Y:2015 | 11 | 2015 | INSULATE BARE EQUIPMENT | $341 | $208 | Not Implemented |
OK0912 # 08 Y:2015 | 08 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $64 | $46 | Implemented |
OK0912 # 10 Y:2015 | 10 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,628 | $60,000 | Not Implemented |
OK0910 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,309 | $1,250 | Implemented |
OK0910 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,664 | $8,092 | Not Implemented |
OK0910 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $70,459 | $247,939 | Implemented |
OK0910 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,605 | $6,953 | Not Implemented |
OK0910 # 02 Y:2015 | 02 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $42,177 | $162,050 | Not Implemented |