Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

825

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0073 # 06 Y:1983 06 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,873 $4,897 Not Implemented
OK0073 # 07 Y:1983 07 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $643 $1,765 Not Implemented
OK0073 # 08 Y:1983 08 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $333 $1,117 Not Implemented
OK0073 # 09 Y:1983 09 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,659 $490 Not Implemented
OK0073 # 10 Y:1983 10 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,063 $270 Not Implemented
OK0073 # 11 Y:1983 11 1983 HEAT WATER WITH EXHAUST HEAT $54,540 $36,000 Implemented
OK0073 # 12 Y:1983 12 1983 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $6,511 $27,000 Not Implemented
OK0073 # 13 Y:1983 13 1983 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $471 $477 Not Implemented
OK0073 # 14 Y:1983 14 1983 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $79 $136 Not Implemented
OK0043 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $58 $34 Implemented
OK0043 # 02 Y:1982 02 1982 INSTALL TURBULATORS $137 $670 Not Implemented
OK0043 # 03 Y:1982 03 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $33 $600 Implemented
OK0043 # 04 Y:1982 04 1982 INSTALL / REPAIR INSULATION ON STEAM LINES $2,200 $210 Implemented
OK0043 # 05 Y:1982 05 1982 HEAT WATER WITH EXHAUST HEAT $453 $1,384 Not Implemented
OK0021 # 01 Y:1982 01 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $417 $225 Not Implemented
OK0021 # 02 Y:1982 02 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,873 $1,425 Not Implemented
OK0021 # 03 Y:1982 03 1982 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $3,426 $24,000 Not Implemented
OK0021 # 04 Y:1982 04 1982 TURN OFF EQUIPMENT WHEN NOT IN USE $12,842 $0 Not Implemented
OK0021 # 05 Y:1982 05 1982 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $6,552 $6,300 Not Implemented
OK0021 # 06 Y:1982 06 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,950 $1,500 Not Implemented
OK0021 # 07 Y:1982 07 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $266 $4,572 Implemented
OK0021 # 09 Y:1982 09 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,184 $8,662 Not Implemented
OK0019 # 01 Y:1982 01 1982 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $624 $0 Not Implemented
OK0019 # 02 Y:1982 02 1982 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $413 $100 Not Implemented
OK0019 # 03 Y:1982 03 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $539 $570 Implemented