Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,706
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0244 # 04 Y:2006 | 04 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,614 | $0 | Not Implemented |
SU0244 # 05 Y:2006 | 05 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $93,478 | $10,000 | Not Implemented |
SU0244 # 06 Y:2006 | 06 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $16,219 | $432 | Implemented |
SU0244 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,070 | $1,038 | Implemented |
SU0244 # 08 Y:2006 | 08 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,016 | $5,266 | Not Implemented |
SU0244 # 09 Y:2006 | 09 | 2006 | INSULATE FEEDWATER TANK | $3,113 | $2,058 | Implemented |
SU0244 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,277 | $20,000 | Implemented |
SU0244 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $448 | $356 | Implemented |
SU0244 # 12 Y:2006 | 12 | 2006 | OPTIMIZE PLANT POWER FACTOR | $11,590 | $30,856 | Not Implemented |
SU0244 # 13 Y:2006 | 13 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $1,187,734 | $4,100,000 | Not Implemented |
IC0121 # 01 Y:2006 | 01 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,152 | $4,984 | Implemented |
IC0121 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,664 | $700 | Implemented |
IC0121 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,928 | $9,302 | Not Implemented |
IC0121 # 04 Y:2006 | 04 | 2006 | INSTALL TURBULATORS | $7,715 | $23,253 | Not Implemented |
IC0121 # 05 Y:2006 | 05 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $20,185 | $115,000 | Not Implemented |
IC0121 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $440 | $1,664 | Implemented |
IC0121 # 07 Y:2006 | 07 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $18,627 | $88,113 | Not Implemented |
IC0121 # 08 Y:2006 | 08 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,394 | $27,491 | Implemented |
IC0121 # 09 Y:2006 | 09 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,933 | $89,400 | Not Implemented |
SF0333 # 01 Y:2006 | 01 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $65,964 | $9,840 | Not Implemented |
SF0333 # 02 Y:2006 | 02 | 2006 | USE COMPRESSOR AIR FILTERS | $3,806 | $1,200 | Not Implemented |
SF0333 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,592 | $4,815 | Not Implemented |
SF0333 # 04 Y:2006 | 04 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,439 | $600 | Not Implemented |
SF0333 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,301 | $4,440 | Not Implemented |
SF0333 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,924 | $17,809 | Not Implemented |