Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,706
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0256 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $20,392 | $3,960 | Implemented |
LL0256 # 05 Y:2006 | 05 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,350 | $720 | Not Implemented |
LL0256 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $7,057 | $1,330 | Implemented |
LL0256 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,368 | $30 | Not Implemented |
LL0256 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $2,768 | $210 | Not Implemented |
LL0256 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,347 | $640 | Implemented |
LL0256 # 10 Y:2006 | 10 | 2006 | USE PHOTOCELL CONTROLS | $870 | $90 | Implemented |
LL0256 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $785 | $700 | Implemented |
OR0501 # 01 Y:2006 | 01 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $119,000 | $200 | Implemented |
OR0501 # 02 Y:2006 | 02 | 2006 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $72,600 | $1 | Implemented |
OR0501 # 03 Y:2006 | 03 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $41,300 | $59,700 | Implemented |
OR0501 # 04 Y:2006 | 04 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $31,700 | $105 | Implemented |
OR0501 # 05 Y:2006 | 05 | 2006 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $25,000 | $3,400 | Not Implemented |
OR0501 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $8,560 | $100 | Implemented |
OR0501 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,100 | $0 | Implemented |
CO0585 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,850 | $15,000 | Not Implemented |
CO0585 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,420 | $180 | Implemented |
CO0585 # 03 Y:2006 | 03 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,160 | $3,230 | Not Implemented |
CO0585 # 04 Y:2006 | 04 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,120 | $0 | Implemented |
CO0585 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $142 | $194 | Implemented |
CO0585 # 06 Y:2006 | 06 | 2006 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $3,460 | $29,620 | Not Implemented |
CO0585 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,720 | $3,590 | Implemented |
CO0585 # 08 Y:2006 | 08 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,430 | $2,950 | Not Implemented |
CO0585 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $719 | $110 | Implemented |
CO0585 # 10 Y:2006 | 10 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $290 | $200 | Implemented |