Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,706
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0351 # 14 Y:2004 | 14 | 2004 | INSTALL STEAM TRAP | $9,570 | $7,950 | Implemented |
IA0351 # 15 Y:2004 | 15 | 2004 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $1,998 | $250 | Implemented |
LL0205 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,430 | $1,080 | Implemented |
LL0205 # 02 Y:2004 | 02 | 2004 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $3,365 | $1,868 | Not Implemented |
LL0205 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,158 | $30 | Not Implemented |
LL0205 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,067 | $162 | Not Implemented |
LL0205 # 05 Y:2004 | 05 | 2004 | USE PHOTOCELL CONTROLS | $555 | $120 | Not Implemented |
LL0205 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $521 | $180 | Not Implemented |
LL0205 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $393 | $245 | Not Implemented |
LL0205 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,750 | $1,820 | Implemented |
OK0695 # 01 Y:2004 | 01 | 2004 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $35,493 | $329,564 | Not Implemented |
OK0695 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,436 | $17,500 | Not Implemented |
OK0695 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,386 | $4,515 | Not Implemented |
OK0695 # 04 Y:2004 | 04 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,723 | $21,750 | Implemented |
OK0695 # 05 Y:2004 | 05 | 2004 | COMBINE UTILITY METERS | $2,354 | $2,546 | Not Implemented |
OK0695 # 06 Y:2004 | 06 | 2004 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $6,830 | $0 | Implemented |
OK0695 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,073 | $23,985 | Not Implemented |
LE0199 # 01 Y:2004 | 01 | 2004 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $37,230 | $16,000 | n/a |
LE0199 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $9,780 | $15,000 | Not Implemented |
LE0199 # 03 Y:2004 | 03 | 2004 | INSULATE FEEDWATER TANK | $8,188 | $2,220 | Implemented |
LE0199 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,404 | $300 | Implemented |
LE0199 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,019 | $1,884 | Not Implemented |
LL0204 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,973 | $20,331 | Implemented |
LL0204 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $6,514 | $360 | Implemented |
LL0204 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $6,025 | $3,880 | Implemented |